CHAPTER 5: PNEUMATICS
49
QUICK LOAD SERVO S3T
2.
AIR UNIT
2.1. Description
The air filtering device serves to filter air and to set its pressure before it is distributed into the pneumatic
circuit of the bar feeder.
The air must be supplied at a minimum pressure of 5 bar and, whenever possible, clean and dry.
2.2. Layout of the elements
2.3. Connections
The pneumatic connection (
C
) is located behind the electrical cabinet.
For the pneumatic connections of the bar feeder, the customer must provide a pipe (
B
) with an inside
diameter of 1/2" (12.7 mm).
Provide an air hose long enough to allow the complete travel (500 mm) of the retraction system to be
used.
When the pipe is connected, it should not trail on the
ground as it could be damaged.
1.
Place a clamp (
A
) around the pipe (
B
)
2.
Push the pipe (
B
) onto the fitting (
C
)
3.
Tighten the clamp (
A
) to make it airtight.
2.4. Settings
1.
Unlock the adjusting knob by pulling it upward.
To increase the pressure, turn it clockwise. To decrease it, turn
it in the opposite direction.
The service pressure should be set at 5 bar.
2.
When the settings are done, lock the adjusting knob by pushing
it downward.
Designation Description
A
Pressure regulator
B
Pressure gauge with pressure control unit
C
Inlet
D
Regulated outlet to the pneumatic battery
E
Decanter/Tank
F
Automatic purging
C
A
B
A
C
B
E
D
F
Summary of Contents for SERVO S3 T
Page 2: ......
Page 5: ...CHAPTER 1 BASIC PRINCIPLES 3 QUICK LOAD SERVO S3T CHAPTER 1 BASIC PRINCIPLES...
Page 11: ...CHAPTER 2 TECHNICAL DATA 9 QUICK LOAD SERVO S3T CHAPTER 2 TECHNICAL DATA...
Page 18: ...16 CHAPTER 2 TECHNICAL DATA QUICK LOAD SERVO S3T...
Page 19: ...CHAPTER 3 SYSTEM START UP 17 QUICK LOAD SERVO S3T CHAPTER 3 SYSTEM START UP...
Page 35: ...CHAPTER 4 ELECTRICS 33 QUICK LOAD SERVO S3T CHAPTER 4 ELECTRICS...
Page 45: ...CHAPTER 4 ELECTRICS 43 QUICK LOAD SERVO S3T 3 ELECTRIC DIAGRAMS...
Page 49: ...CHAPTER 5 PNEUMATICS 47 QUICK LOAD SERVO S3T CHAPTER 5 PNEUMATICS...
Page 54: ...52 CHAPTER 5 PNEUMATICS QUICK LOAD SERVO S3T...
Page 55: ...CHAPTER 6 GENERAL DESCRIPTION 53 QUICK LOAD SERVO S3T CHAPTER 6 GENERAL DESCRIPTION...
Page 73: ...CHAPTER 7 OPERATION 71 QUICK LOAD SERVO S3T CHAPTER 7 OPERATION...
Page 105: ...CHAPTER 8 MALFUNCTIONS MAINTENANCE 103 QUICK LOAD SERVO S3T CHAPTER 8 MALFUNCTIONS MAINTENANCE...
Page 116: ...114 CHAPTER 8 MALFUNCTIONS MAINTENANCE QUICK LOAD SERVO S3T...
Page 117: ...CHAPTER 9 APPENDICES 115 QUICK LOAD SERVO S3T CHAPTER 9 APPENDICES...