4.5.4. Motor protector settings chart
Model
Connection voltage
[V]
Electric motor power
(kW)
Current draw
[A]
Motor protector settings
[A]
SC 500
230V 50 Hz Single-
phase
0.37
3
3
115V-60 Hz Single
phase
0,44
7
7
400V 50 Hz 3Ph
0.37
1.09
1.09
200 V 50 Hz 3Ph
0.37
1.86
1.86
220-230V 60 Hz-3 Ph
0.44
2.04
2.04
400 V 60 Hz 3Ph
0.44
1.18
1.18
460 V 60 Hz 3Ph
0.44
1.09
1.09
5. Unit use
5.1. Starting and stopping
To start the unit:
·
Press the motor protector switch start button located at the bottom right
·
Press the green start/stop button located on the right or left hand side of the cabin
·
Place one foot below the proximity sensor for start.
8a) motor protector switch
8b) green start/stop button
8c) proximity sensor for start
The LED light tube turns on to indicate that the cabin is running.
The spray cabin will automatically turn off after about 3 minutes.
Press the green button if you want to stopping in advance the functioning of cabin without having to wait the