APPENDIX A
Table 1 The LU 7.2 Status formation algorithm
No
Lift Unit State
State condition
1
Maintenance mode
Service key installed or service tool connected
2
Firmware restart
Lift Unit microprogram restart
3
Multiple door reversing
Miltiple door opening-closing without cabin motion (number of
reversals-address 4 of NVRAM)
4
Machine room penetration
Door sensor is open, service key not installed
5
Cabin door opening
Inner algorithm
6
Lift cabin movement detected
Inner algorithm
7
Cabin door starts opening
Inner algorithm
8
Landing door opening
Inner algorithm
9
Lift is not powered
No voltage at Safety Chain Begin check point
10
“STOP” button clamped
11
Door opened
12
Safety chain open
No voltage on Safety Chain End check point while Safety
Chain Begin check point is powered
13
Door is not closed
No Door Closing signal after Door Opening signal
14
Safety chain short circuit
Simultaneous presence of UP/DOWN signals and Door Closing
/Door Opening signals
15
Dispatcher call
Closing "CALL" and "Common/Ground" terminals
16
Unauthorized cabin movement
Impulses from OGS while impulses "UP"/"DOWN" are absent
17
Main drive fault
Cabin upward/downward motion while no impulses from OGS
18
Door drive fault
Continuous signal either of Door Opening or Door Closing
19
Shaft penetration
Door Closed without Up/Down signals, as well closing more
than two Door Closed contacts
20
Safety device fault
Door locker's contact bounce
21
Out of service
Lift is switched to maintenance mode manually, no link with
controller, or critical error from controller received
22
Machine room open
MR door sensor is open while service key is installed
23
Voltage at safely chain begin
checkpoint
Voltage at Safety Chain Begin check point
24
Movement with safety chain open
Either of "UP"/"DOWN" impulses present while safety chain is
open
25
Cabin between floors
No "Door opening" signal after "UP"/"DOWN" impulse
completion (status can be cleared only after “UP”/”DOWN”
signals appear)
26
Cabin door sensor malfunction
27
Lack of serial port communication
No link with the Lift Controller or the RSA via serial interface
28
Main drive is ON
Either of "UP" or "DOWN" signals appear
29
User Bit
Signal on XP4 pin 4
30
Reserved
31
Reserved
32
Reserved
-
Full stop of cabin by inertia