![LKDS LNGS.465213.270-10 Operation Manual Download Page 10](http://html1.mh-extra.com/html/lkds/lngs-465213-270-10/lngs-465213-270-10_operation-manual_1931899010.webp)
LNGS.465213.270-10 OM
Page 10
warning on the lift safety chain changes;
identification of incoming warnings (where from and what signal is received);
incoming warnings identification;
lift control station logging;
discovering and logging faults and error messages of the lift;
detecting machine room/control cabinet penetration;
remote lift shutdown by command from dispatcher (optional);
supporting voice devices located in the cabin, on the cabin roof, in the machine room, pit and on landing
platforms;
voice communication system self test;
floor number arrival messaging;
audio background (microSD card is required);
voice announcement remote renewal;
remote firmware updating.
Based on information received from a lift control board, a lift unit forms the following standard statuses:
Lift is not powered (connection with control board is established);
“STOP” button clamped;
11
Safety chain short circuit;
2
Safety chain open;
Cabin door opened;
1
Multiple door reversing;
Door drive fault;
Dispatcher call;
Unauthorized cabin movement;
Main drive fault;
Shaft penetration;
3
Out of service;
Machine room penetration;
Machine room open;
Maintenance mode;
Cabin between floors;
Cabin door sensor fault;
1
Lack of serial port communication;
2
Lift unit failure;
Voltage at safely chain begin checkpoint;
USER1 state;
USER2 state;
USER3 state;
USER4 state;
No mains power;
Safety circuit AC voltage.
2
Lift unit options LNGS.465213.270-11, LNGS.465213.270-
14 … LNGS.465213.270-20, LNGS.465213.270-22 …
LNGS.465213.270-94, LNGS.465213.270-
96 … LNGS.465213.270-119 makes it possible to generate additional
statuses, based on the data received via serial interface.
DELIVERY SET
The LU completeness depends on the option, and shown in Appendix B.
LIFT UNIT DEVICE
1
Not generated for LU LNGS.465213.270-10
2
Status generated for LU LNGS.465213.270-10 only
3
In the presence of free normally open contacts of Door closed (Landing door) switches on the lift - only for the
execution of the LNGS.465213.270-10 option or the presence of information in the serial channel of the lift control
station.