LXC92X0 Controller is panel built-in design; it is fixed by clips when installed. The controller’s overall
dimensions and cutout dimensions for panel, please refers to as following.
This
This
This
This section
section
section
section contains
contains
contains
contains a
a
a
a number
number
number
number of
of
of
of very
very
very
very important
important
important
important considerations.
considerations.
considerations.
considerations.
Controller installation instructions notes
NO.
NO.
NO.
NO.
IIIItem
tem
tem
tem
Note,Warning,Caution
Note,Warning,Caution
Note,Warning,Caution
Note,Warning,Caution
Description
Description
Description
Description
1
Voltage
Input
:8
~
35VDC
Negative of battery must be connected with the shell of starter stable.
2
Connect
controller
to battery
:Wire ≥2.5mm²
The diameter of wire which from power supply to battery must
be over 2.5mm².
3
Battery
Charger
:Charger must be
connected directly to
the battery.
Please firstly connect output wires of charger to battery’s positive
and negative directly, then, connect wires from battery’s positive
and negative to controller’s positive and negative input ports in
order to prevent charge disturbing the controller’s normal working.
4
Speed
Sensor
Input
:2 cores
shielding line
Speed sensor is the magnetic equipment which be installed in starter
and for detecting flywheel teeth.Its connection wires to controller
should apply for 2 cores shielding line. The shielding layer should
connect with No.18 terminal in controller while another side is
hanging in air.The else two signal wires are connected with No.17
and No.18 terminals in controller.The output voltage of speed sensor
should be within (1~24) VAC (effective value) during the full speed.
5
Output
And
Expand
Relays
:Please add freewheel
diode to both ends of
expand relay's coils
or,increase
resistance-capacitance
return circuit
All outputs of controller are relay contact output type.If need to
expand the relays, please add freewheel diode to both ends of
expand relay’s coils (when coils of relay has DC current) or,
increase resistance-capacitance return circuit (when coils of
relay has AC current), in order to prevent disturbance to
controller or others equipment.
6
AC Input
:ICOM port must be
connected to negative pole
of battery controller power.
:When there is load
current, transformer’s
secondary side prohibit
from open circuit.
Current input of controller must be connected to outside
current transformer.And the current transformer’s secondary
side current must be 5A. At the same time, the phases of
current transformer and input voltage must correct. Otherwise,
the current of collecting and active power maybe not correct.
7
Withstand
Voltage
Test
::::
When controller had been installed in control panel, if need the high voltage test, please disconnect
controller’s all terminal connections, in order to prevent high voltage into controller and damage it.