SAFETY INSTRUCTIONS

Before Getting Started

2

Risk of severe injury or death by electrical shock.

To reduce risk of electrical shock, disconnect power before working on or around the system.

Wire pump system for correct voltage.

Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device if required by 

code. 

Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly connected.

Some pumps are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock, be 

certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove the third prong from the plug. 

The third prong is to ground the pump to help prevent possible electric shock hazard. 

Some pumps are supplied with lead wires and are intended to be hardwired using a junction box or other approved enclosure. 

The pumps include a grounding connector. To reduce risk of electric shock, be certain that it is properly connected to ground.

In a 230 V direct wire installation, one side of the line going to the pump is always electrically energized, regardless of whether 

the liquid level control switch is open or closed. To avoid hazards when installing or servicing, install a double-pole disconnect 

near the pump installation.

The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception of shortening the 

cord to fit into a control panel. Any splice between the pump and the control panel must be made within a junction box and com

-

ply with the National Electrical Code.

Check local electrical and building codes before installation. The installation must be in accordance with their regulations as well 

as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

Do not use the power cord for lifting the pump.

Do not use an extension cord.

The pump should only be used with liquids compatible with pump component materials. If the pump is used with liquids incom

-

patible with the pump components, the liquid can cause failure to the electrical insulation system resulting in electrical shock.

Risk of bodily injury, electric shock, or equipment damage.

This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in experi

-

ence and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with the unit or in 

the immediate vicinity.

Equipment can start automatically. Lockout-Tagout before servicing equipment.

An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage.

Operation of this equipment requires detailed installation and operation instructions provided in this manual. Read entire manual 

before starting installation and operation. End User should receive and retain manual for future use.

Risk of damage to pump or other equipment.

Before installing pump, allow air conditioner to cycle several times, collecting condensate in a separate container to help flush any 

residual oils that may remain in the system. Failure to flush the system can result in damage to the pump and drain line plumbing 

components.

When operating in a gas furnace environment, care must be taken to ensure acidity of condensate does not fall below the average 

pH of 3.4 (to prevent a localized pocket of acid that acts like a battery causing pitting) by routinely cleaning or flushing tank with 

fresh water.

Support pump and piping when assembling and when installed. Failure to do so may cause piping to break, pump to fail, motor 

bearing failures, etc.

Do not install the pump in a manner that will subject it to splashing or spraying.

Periodically inspect pump and system components. Regularly check hoses for weakness or wear, making certain that all connec

-

tions are secure.

Schedule and perform routine maintenance as required and in accordance with the Maintenance section of this manual.

Pump is for indoor use only.

Do not use this pump inside an air plenum.

Summary of Contents for VCMA Series

Page 1: ...l and local electrical and plumbing codes and within Little Giant recommendations may result in electrical shock or fire hazard unsatisfactory performance or equipment failure Know the product s appli...

Page 2: ...The pump should only be used with liquids compatible with pump component materials If the pump is used with liquids incom patible with the pump components the liquid can cause failure to the electric...

Page 3: ...ameter maximum tubing or piping to prevent excessive flow back to unit 4 Route outlet tubing straight up not exceeding 75 of total dynamic head capacity of the pump 5 At the top slope discharge line d...

Page 4: ...age circuit in the event of high water level activating an external alarm or relay purchased separately Use the following proce dure if an NC configuration is required Remove the pump s motor cover 4...

Page 5: ...mponents follow these steps 1 Disconnect the pump from the power source 2 Remove tank cover assembly from the tank The cover snaps on to the reservoir Pull out on the slot on the long side of the top...

Page 6: ...vy to operate correctly Check valve stuck or plugged Remove check valve and inspect for proper operation Outlet flow is blocked Check outlet tubing to ensure that it is not kinked or blocked Clear blo...

Page 7: ...equipos y procedimientos adec uados El hecho de no cumplir con los c digos el ctricos y de plomer a nacionales y locales y con las recomendaciones de Little Giant puede provocar peligros de descarga...

Page 8: ...r la bomba No use un prolongador La bomba solo se debe utilizar con l quidos compatibles con los materiales que componen la bomba Si la bomba se utiliza con l quidos incompatibles con los componentes...

Page 9: ...orriente y aseg rela con la abraza dera de manguera no suministrada Utilice 3 8 pulgada de di metro interior m ximo tuber a para evitar un flujo excesivo de vuelta a la unidad 4 Dirija la tuber a de s...

Page 10: ...raci n 2 El instalador puede reconfigurar este interruptor al terminal NC para cerrar un circuito de voltaje bajo en el caso de nivel de agua alto lo que podr a activar un rel o una alarma externa que...

Page 11: ...ccionar y limpiar el tanque y otros componentes siga los pasos que se detallan a continu aci n 1 Desconecte la bomba de la fuente de alimentaci n 2 Quite el conjunto de la cubierta del tanque La cubie...

Page 12: ...salida est bloqueado Verifique la tuber a de salida para asegurarse de que no est retorcida ni bloqueada Despeje la tuber a bloqueada de lodo y residuos Limpie la tuber a de entrada y de salida El imp...

Page 13: ...es recommandations de Little Giant pourrait mener une lectrocution ou un incendie une mauvaise performance ou une d faillance de l quipement Lisez et suivez attentivement les instructions pour viter t...

Page 14: ...e ce soit Il peut uniquement tre raccourci si cela est n cessaire pour le faire rentrer dans le panneau de commande Toute pis sure entre la pompeet le panneau de commandedoit tre r alis edans unebo te...

Page 15: ...rieur maximum tubulure ou tuyauterie pour viter un coulement excessif de retour l unit 4 Acheminez la tubulure de sortie de la pompe vers le haut Ne d passez pas 75 de la charge hydraulique gal h de...

Page 16: ...ompe La pompe doit tre connect e ou branch e sur son propre circuit sans autre prise ou quipement sur la ligne du circuit Ne le raccordez pas un ventilateur ou tout dispositif fonctionnant par inter m...

Page 17: ...d activer une alarme ou un relais externe vendus s par ment Utilisez la proc dure suivante si une configuration NC est requise Retirer le couvercle du moteur de la pompe 4 Soutenir l interrupteur et p...

Page 18: ...posants suivez ces tapes 1 D branchez l alimentation de la pompe 2 Retirez l ensemble de capot du r servoir Le capot se fixe au r servoir par pression Tirez sur la fente situ e sur le c t long de la p...

Page 19: ...elle n est pas coud e ou obstru e Nettoyez la boue et les d bris de tout tuyau obstru Nettoyez la tuyauterie d entr e et de sortie La roue de la pompe ne tourne pas Nettoyez toute obstruction dans le...

Page 20: ...ic Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Form 998086 R v 002 03 20 Droits d auteur 2020 Franklin Electric Co Inc Tous...

Reviews: