Rev: 05.20.2022
Page 7
CCD-0001745
Fig. 6
Note:
If the auto level sequence does not perform as described, place the system in manual mode and
test that the jacks operate correctly by pressing their coordinating buttons on the touchpad; i.e.,
pressing the FRONT button only operates the front jacks.
Hitch Recognition
1.
Turn on the touchpad.
2.
Push the Up Arrow (Fig. 6A) to scroll to "Auto Reconnect" option on the LCD screen.
3.
Push ENTER (Fig. 6B). The rear jacks and middle jacks (if equipped) will retract first, then the front jacks
will extend to raise the 5th Wheel to the height where the auto level sequence was started.
Note:
If the auto level sequence was started with the front of the 5th Wheel in a below-level condition,
the Hitch Recognition will not function and the LCD will display “Feature Disabled.” For the Hitch
Recognition feature to function, the auto level sequence must be started with the front of the
5th Wheel above level.
A
B
System Settings
Homing Jacks
When certain components are added or replaced the system will need to be homed.
1.
Run the system by pressing FRONT (Fig. 1G). A special jack error code should occur. If not, introduce
the special jack error code.
A.
To introduce an error, disconnect one of the hall effect sensor wires from the controller.
I.
After attempting to operate the disconnected jack, the touchpad screen will display an error.
II.
Reconnect the hall effect sensor wire.
B.
To clear the special jack error code, the jacks need to be homed.
C.
To "home" the jacks, each jack must be able to retract a minimum of 6".
2.
Extend all jacks to reach the 6" of minimum retract needed as follows:
A.
Press FRONT button (Fig. 1G) to extend the front jacks, if required.
B.
Press REAR button (Fig. 1J) to extend the rear jacks, if required.
C.
Press LEFT and RIGHT buttons (Fig. 1H and Fig. 1I) simultaneously to extend the middle jacks, if
equipped and required.
3.
Press and hold the RETRACT button (Fig. 1D) until all of the jacks begin to retract. The jacks will
continue to retract until they reach the hard current limit.
4.
The jacks are now homed and the special jack error code will be cleared.
Note:
If the jacks do not retract, an error should display on the LCD display. This is typically caused by a
wiring interruption.