Rev: 05.20.2022
Page 21
CCD-0001745
A
Jack Motor Replacement
1.
Disconnect the motor's cables from the system harness.
2.
Using a
1/2"
socket or wrench, remove the two motor retention bolts from the jack (Fig. 30A).
3.
Remove the faulty motor from the top of the jack (Fig. 31).
4.
Gently engage the new motor's drive coupler with the jack leg's drive shaft.
5.
Reinstall and tighten motor retention bolts.
6.
Reconnect system harnesses to the motor's cables.
Note:
LCI recommends zip-tying the harnesses tight to prevent damage to the harnesses.
When components are added or replaced, the system will need to be homed.
1.
Run the system by pressing the FRONT button (Fig. 1G).
A.
A special jack error code should occur.
B.
If not, introduce the special jack error code.
I.
To introduce an error, disconnect one of the hall effect sensor wires from the controller.
II.
After attempting to operate the disconnected jack, the touchpad screen will display an error.
III.
Reconnect the hall effect sensor wire.
2.
To clear the special jack error code, the jacks need to be homed. See Homing Jacks section.
Fig. 30
Fig. 31