E - OPERATOR MANUAL
8695 4387 / H
E-16
EASYTOME
3 - STARTING UP
Procedure for the machine
Turn the disconnector of the electrical cabinet
Press the Start PC button
Press and hold down the green reset button
Procedure for the extraction system
NB: the remote controls must be connected to the extraction control unit (optional service from the fitter)
Select the manual or automatic mode
Manual mode: extraction starts when the manual On button is pressed
Automatic mode: extraction starts automatically at the start of the automatic cutting cycle of the program
4 - STOPPING THE MACHINE
Procedure for the machine
Use the emergency stop button
Use the On/Off button or the Windows shutdown button on the PC
When the PC has shut down, turn the disconnector of the electrical cabinet
Procedure for the extraction system
Manual mode: extraction stops when the manual Off button is pressed
Automatic mode: extraction stops automatically at the end of the automatic cutting cycle of the program
If the operator is away for an extended period of time or if any work is done on the cutting tools, the energy
supplies must absolutely by shut off
Caution! The rotary switch on electrical cabinet only isolates the gantry machine,
but not the plasma cutting process or the extraction system