D - ASSEMBLY AND INSTALLATION
8695 4387 / H
D-12
EASYTOME
Equipotential bonding:
Caution! The machine requires equipotential bonding between the
table and the earth of the customer’s building.
LINCOLN ELECTRIC supplies the required connection:
W000260272
WELDING CABLE H01N2D 16MM 2
W000010094
Screw lug, diam 11mm - 0-25mm2
The machine table may be made up of several modules. Make sure that an equipotential cable is connected
between the different modules.
Schematic diagram of the equipotential connection:
Pneumatic:
Lincoln Electric recommends the supply of pneumatic supplies as recommended in the layout drawing
W000379245. Excerpt:
System air
Dry and oil free air
Hose connector Ø 10
Hose connector Ø 6
Table
5m3/h
7bar ±0,5
Nertajet 40i
: 13 m3/h or 220 l/min, 7bar ±1
FLEXCUT125CE
, 15,6 m3/h (260 l/min), 6,21 to 8,27 bar
The valves must be lockable with venting on all feeders.
Filter and extraction connections: please refer to the corresponding instructions
Equipotential link
Equipotential cable
table modules
Plasma
_
+
Building
earth 5 ohms
max