Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2011 – Linkcom – All rights reserved
15
Parameter Value
Description
Default
61
z
Acoustic signaling
(confirmation, error, empty
memory, call termination...)
(0/1)
1
In default the stages of door intercom are acoustically signalling.
z=0 – signaling is off
z=1 – signaling is on
Parameter Value
Description
Default
62
v
Acoustic signaling off hook/on hook (0/1)
1
In default is signaling pick up and hang up of the line. If you identify some problems at certain PBXs you
can switch it off.
z=0 – signaling OFF HOOK / ON HOOK is off
z=1 – signaling OFF HOOK / ON HOOK is on
Parameter Value
Description
Default
63
u
Acoustic signaling knocking to call (0/1)
0
With this feature, you can identify at PBX calling from the doorphone just up knocking into call.
u=0 – knocking to call is off
u=1 – knocking to call is on
Parameter Value
description
Default
65
z
Acoustic signalling of relay activation (0/1)
0
When you activate this feature
z=1
, you hear a special sounds that simulating the relay activation.
During relay activation you hear special sounds simulating relay activation.
Parameter Value
Description
Default
66
i
Suppression of DTMF reception from
microphone
(0/1)
0
In default the suppression of DTMF reception from MIC is off
i=0
. Due this you can activate relay by
personal dialer without ringing to person inside building. To increase security you can activate suppression
of DTMF reception from microphone
i=1
.
Parameter Value
Description
Default
67
b
BabyCall – call without necessity program
phone number
(0/1)
0