Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2011 – Linkcom – All rights reserved
21
87
Default setting for Parameters 7x only
80
Default setting for Parameters 0x only
9
END
6. Technical parameters
6.1. Electrical parameters
Parameter
Value
Conditions
Minimal line current
18mA
Line OFF HOOK
Minimal line voltage
18V
Line ON HOOK
Line voltage during OFF
HOOK (VA characteristic)
< 8V
< 12V
I = 20mA
I = 60 mA
Downlead during ON HOOK
< 30uA
U = 60V
Line termination impedance
220R +
820R
paral. 115nF
Line OFF HOOK
Bandwidth
300Hz – 3400 Hz
20 - 60mA
Ringing impedance
> 2Kohm
25 – 60 Hz
Sensitivity of ringing
detector
min. 10 – 25 V
Pulse dial
40 / 60 ms
Tone dial level
-6 and -8 dB
20 – 60 mA
Sensitivity of tone dial
min. -40 dB
20 – 60 mA
Sensitivity of tones detector
min. -30 dB
20 – 60 mA
Powering of backlight, relays
and heating
12Vss ± 2V , 10-12Vst ± 2V
Max consumption of
backlight and heating
250mA
12Vss
Max voltage of relay contact
48V
when I < 1A
Max current of relay contact
1,5A
when U < 30 V
Operation temperature
-20 to +60°
IP rate
IP44
Weight
max. 350g
6.2. Mechanical dimensions
Model
dimension HxWxD [mm]
Brave Slim
185 x 99 x 40
Screw 2x
Screw 3.5x30 half round head
Wall plug 2x
UPA,UPP pr. 5 x 25