By activation this feature (
b=1)
is cancelled acoustic signaling of empty memory. After pushing of button
with empty memory you get just beep (confirmation) and call is established as normal dialed number
Caution:
first 10sec of call is not active tone detector (it waits on reaction of PBX and number dialing by
PBX)
Parameter Value
Description
Default
6*
t
Delay of line connection (Siemens pbx)
(0/1)
0
Sets a delay for line pick-up (OFF HOOK) for new PBX types (particularly Siemens):
t=1 – standard operation
t=0 – delayed start
5.6. HandsFree Parameteres setting
Parameter Value
Description
Default
71
gg
Reception loudness (01-16)
(TRH)
07
72
ff
Transmission loudness (01-16)
(MIC)
07
73
rr
Speaker loudness (01-16)
(SPK)
07
gg / ff / rr
– 2 digits in range [01-16]
After reception of confirmation, the new value is active and you can test it.
Help: you can also add / decrease the amplification with the phone buttons:
*
=
-
and
#
=
+.
The Limits of maximal and minimal loudness are acoustically signaling by 3 tones. When you don’t press
any digit during 5 seconds, the setup value is saved and you hear confirmation tone.
Parameter Value
Description
Default
74
c
Soft pass of switching (0/1)
0
It is going about character of on line operation semiduplex switching. In case where character of
depressed is too steep you can make it softer by
c=1
.
Parameter Value
Description
Default
75
n
Depression of background sound (0/1)
0