POST MOUNTING INSTRUCTIONS FOR MODEL 

GSLG-A

SIDE PLATE INSTALLATION

Before installing, make sure the gate rolls or slides freely, 
and that all exposed rollers are properly covered. The gate 
must be covered with fabric with openings no larger than 
2 1/4” in size, to a minimum height of 48 inches from ground 
level. On picket-style gates, if pickets are spaced less than 
2 1/4” apart, mesh is optional.

Use two 3 - 3 1/2” OD galvanized posts and secure with 
concrete footings as shown, length to be determined by lo-
cal codes, frost line depth and soil conditions. Secure the 
operator to the posts using the 4” U-bolts, side plates, 
and hardware. There are a total of eight side plates. There 
are six 3/16” side plates which should be mounted on the 
outside top and bottom of the cabinet, two 3/16” side plates which 
go on the top inside and two 1/2” side plates which should be 
mounted on the inside top of the cabinet as shown in the illustra-
tion at the right.

To assemble the drive chain and gate brackets, refer to page 

6

Make sure that the chain sag does not exceed recommended 
sizes and that the chain does not come into contact with the 
moving parts of the gate or ground.

For optional pad mounting instructions, see LINEAR drawing 
#2700-360.

The operator is intended for installation only on 

gates used for vehicles. Pedestrians must be sup-

plied with a separate access opening. The pedestrian 
access opening shall be designed to promote pedes-

trian usage. Locate the gate such that persons will 

not come in contact with the vehicular gate during 

the entire path of travel of the vehicular gate.

Summary of Contents for GSLG-A

Page 1: ...L325 COMPLIANCE REQUIRES THE USE OF CONTACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMATIC OR REMOTELY CONTROLLED GATE OPERATORS USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 4...

Page 2: ...tion 11 Onboard L E D Indicator Descriptions 12 Important Notes for Installation of Master Slave Applications 13 Surge Protector Instructions 13 Control and Accessory Connection Illustrations 14 17 IL...

Page 3: ...gate does not seem to operate properly it may affect the operator performance or greatly shorten the life of the unit The gate should be designed so that airflow through the fabric is ample to prevent...

Page 4: ...9 for details of this connection as well as dip switch selection Note The SHIELD wire should be connected in both the master and slave operators e s a h P 3 g n i r i W r e w o P s t l o V P H e c n...

Page 5: ...here are six 3 16 side plates which should be mounted on the outside top and bottom of the cabinet two 3 16 side plates which go on the top inside and two 1 2 side plates which should be mounted on th...

Page 6: ...idler over the drive sprocket and then under the last idler Make sure you feed most of the chain through the sprockets for attaching to the back end of the gate Assemble the other gate bracket on the...

Page 7: ...good working condition One person should be able to move the gate by hand Be certain the gate moves freely and without binding throughout its travel Torque limiters are set light at the factory and mu...

Page 8: ...operator after the limit switch is tripped Once the gate is in this position adjust the open limit nut until it activates the limit switch for open LSO 1 Press down on the detent plate and rotate the...

Page 9: ...of obstructions while running in the closed direction Master Slave Connection Block This terminal block is used in conjunction with two operators to configure two gates to open and close together Dip...

Page 10: ...ain prior to reaching a limit the gate will stop again and this time will sound the emergency alarm and lock out 4 51 CLOSE This function works exactly like the OPEN OBSTRUCTION except that it will on...

Page 11: ...otentiometer higher by 1 1 2 turns for all 115 Volt AC and 24 Volt DC operators and by 3 4 of a turn higher for all 230 Volt AC operators Additional fine adjustment by 1 4 turns may be necessary to el...

Page 12: ...tor wired to the safety loop terminals SHADOW LOOP This indicator is lit when a shadow hold open signal is present This signal is generated by a loop detector wired to the shadow loop terminals This i...

Page 13: ...nd Lock Release Three Second Pre Start Warning Right Left Hand Selections SURGE PROTECTOR INSTRUCTIONS The optional surge protector should be connected to any inputs that have an accessory connected t...

Page 14: ...GSLG A OPERATOR INSTALLATION GUIDE 14 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 15: ...GSLG A OPERATOR INSTALLATION GUIDE 15 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 16: ...GSLG A OPERATOR INSTALLATION GUIDE 16 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 17: ...GSLG A OPERATOR INSTALLATION GUIDE 17 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 18: ...GSLG A OPERATOR INSTALLATION GUIDE 18 LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 17 for details...

Page 19: ...GSLG A OPERATOR INSTALLATION GUIDE 19 EDGE LAYOUT ILLUSTRATION 1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Page 20: ...GSLG A OPERATOR INSTALLATION GUIDE 20 EDGE LAYOUT ILLUSTRATION 2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Page 21: ...GSLG A OPERATOR INSTALLATION GUIDE 21 PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 16 for details...

Page 22: ...GSLG A OPERATOR INSTALLATION GUIDE 22 PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 14 17 for additional details...

Page 23: ...GSLG A OPERATOR INSTALLATION GUIDE 23 TRACK GATE ILLUSTRATION...

Page 24: ...rent sensing set too low Make sure the gate moves freely through its entire travel before ad justing the current sensing B The maximum run timer may have counted down and expired This can be caused by...

Page 25: ...GSLG A OPERATOR INSTALLATION GUIDE 25 MODEL GSLG A MECHANICAL PARTS EXPLODED VIEW...

Page 26: ...s 2500 034 Power Switch only REF NO PART NO DESCRIPTION 46 2100 1756 Mounting Plate 47 2100 1781 Accessory Shelf for single phase models only 33 2400 308 Fender Washer 3 8 34 2400 017 Flat Washer 3 8...

Page 27: ...y 10 2510 249 Input Wire Harness Assembly 11 2510 250 Output Wire Harness Assembly 12 2510 261 Control Box Motor Harness Assembly 13 2500 071 Terminal Strip 16 141 14 2500 212 Transformer 115 24VAC 40...

Page 28: ...0 268 Control Board only 10 2500 1980 3 Phase Motor Board 11 2500 1966 2 Amp Fuse for Control Board 12 2500 1975 3 Amp Fuse for Control Board 13 2510 253 Limit Switch Harness REF NO PART NO DESCRIPTIO...

Page 29: ...ar the source Laboratory samples should be handled in a fume hood Provide mechanical ventilation of confined spaces HANDLING STORAGE AND SHIPPING Keep containers closed Handle and open containers with...

Page 30: ...lace as necessary Check for proper tension and adjust if required Check all pulley setscrews for tightness and tighten if necessary 3 For operators with internal chain drives inspect chain and sprocke...

Page 31: ...GSLG A OPERATOR INSTALLATION GUIDE 31 This page intentionally left blank...

Page 32: ...d that these signs must remain at all times 8 Controls intended for user activation are located at least six feet 6 away from any mov ing part of the gate and where the user is prevented from reaching...

Reviews: