background image

GSLG-A OPERATOR INSTALLATION GUIDE

- 26 -

MODEL 

GSLG-A

 MECHANICAL PARTS LIST

REF
NO. PART 

NO. 

DESCRIPTION

   

2120-359-BT 

Complete Enclosure with Door Assembly

  1 

2120-144-BT 

Enclosure without Door

   

2120-360-BT 

Complete Door and Lock Assembly

   

2300-716 

Stop/Reset Button Cover

   

2500-2192 

C-Face Brake, 115V

   

2500-2397 

C-Face Brake, 208/230/460V

 5 

2110-265 

Rail Assembly

 15 

2100-573 

Spacer Plate

  

2100-661 

Back 

Brace

 12 

2100-1738 

Drive Shaft, 1”

 48 

2400-501 

Retaining Ring

  9  

2200-274 

Bearing, 1”

 43 

2100-1737 

Pillow Block Retaining Plate

 40 

2200-042 

Sprocket, 48 B 15, 1” bore

   

2200-015 

Shaft Collar, 1”

  7 

2120-388 

Torque Limiter Assembly, 5 1/2”

 7A 

2100-1650 

Plate with Solid Pin Groove

 7B 

2100-1661 

Keyed Plate

 7C 

2300-390 

Friction Disc (pair)

 7D 

2200-817 

Belleville Washer

 7E 

2100-1621 

Belleville Washer Retaining Disc

 7F 

2100-1622 

Adjustment Nut

 7G 

2400-407 

Brass Tipped Set Screw

 7H 

2400-416 

Dowel Pin

 7I 

2100-529 

Woodruff Key 

  8 

2210-004 

Sprocket, 40-A-48, with Bearing

 42 

2200-886 

Drive Sprocket, 50-B-20, 1” Bore

   

2110-788 

Gear Reducer/Disconnect Assembly

  2 

2200-920 

Gear Reducer, 15:1

 19 

2120-132 

Shifter Lever Assembly

 18 

2110-362 

Shifter Lever Fulcrum Assembly

 37 

2100-551 

Shifter Lever Rod

 38 

2400-169 

Pal Nut

 20 

2100-1133 

Locking Lever Plate

 28 

2100-910  

Locking Lever

 41  

2200-291 

Shifter and Locking Lever Spring

 14 

2200-014 

Shaft Collar, 1”

 11 

2110-364 

Sprocket, 40 A 24, with Bearing

 30 

2200-549 

Disconnect Collar, 1” (keyed)

 31 

2110-131 

Shifter Block

   

2400-133 

Key, 1/4” x 1/4” x 2 1/4”

 32 

2200-115 

Disconnect Spring

 44 

2510-248 

Stop/Reset Button & Bracket Assembly

   

2100-1760 

Stop/Reset Button Mounting Bracket

  

2500-1495 

Stop/Reset 

Button

 45 

2510-251-D 

Power On/Off Disconnect Assembly

   

 

with Receptacles (115V Models only)

   

2500-1956 

115VAC Duplex Receptacles only

   

2500-1957 

115VAC Switch only

   

2510-252-D 

Power On/Off Disconnect Assembly

   

 

for 230V Models

   

2500-2205 

230VAC Switch only

   

2510-294 

Power On/Off Disconnect Assembly

   

 

for 3-Phase Operators

   

2500-034 

Power Switch only

REF
NO. PART 

NO. 

DESCRIPTION

 46 

2100-1756 

Mounting Plate

 47 

2100-1781 

Accessory Shelf for single phase

  

 

models 

only 

 33 

2400-308 

Fender Washer, 3/8”

 34 

2400-017 

Flat Washer, 3/8”

 35 

2400-016 

Lock Washer, 3/8”

 36 

2400-014 

HHCS, 3/8”-16 x 1”

 
 16 

2110-700 

Idler Assembly

  

2300-697 

UHMW 

Idler 

Wheel

  

2100-1731 

Idler 

Shaft

  6 

2520-173L 

Rotary Limit Box Assembly

  

2500-764 

Limit 

Switch

   

2100-057 

Standard Limit Shaft

  

2200-030 

Limit 

Nut

  

2100-261 

Detent 

Plate

   

2110-162 

Limit Box Enclosure with Cover

   

2100-756 

Limit Box Cover only

       

2200-029 

Flange Bearing, 1/2” ID

  

2200-193 

E-Ring, 

1/2”

  

2400-203 

Spring 

Washer, 

1/2”

   

2200-042 

Limit Drive Sprocket, 48-B-15, 1” bore

   

 

For drives up to 34 feet wide:

 

39 

2200-008 

Limit Box Sprocket, 48-B-10, 1/2” bore

   

2200-922 

#48 Chain, 25 Links

   

 

For drives from 35 to 49 feet wide:

   

2200-041 

Limit Box Sprocket, 48-B-15, 1/2” bore

   

2200-200 

#48 Chain, per foot, 27 Links

   

 

For drives 50 to 65 feet wide:

 

 

2200-276 

Limit Box Sprocket, 48-B-20, 1/2” bore

   

2200-654 

#48 Chain, per foot, 29 Links required

   

 

For drives over 65 feet wide:

   

2200-432 

Limit Box Sprocket, 48-B-30, 1/2” bore

   

2200-654 

#48 Chain, per foot, 32 links required

   

2200-010 

#48 Master Link

   

2200-605 

#40 Chain, 37 Links

   

2200-006 

#40 Master Link

 17 

2100-657-BT 

Rain Cover

 24 

2200-221 

#50 Roller Chain, per foot

   

2200-111 

#50 Master Link

 25 

2100-258 

Chain Pin

 26 

2200-306 

Tension Spring

 22 

2100-2007 

Gate Bracket

 27 

2400-090 

Hex Nut, 1/2”

 23 

2400-170 

Gate U-Bolt

 21 

2400-038 

Mounting U-Bolt

  

2500-867 

Alarm, 

24VAC

   

2510-064 

3-Button Station with Lead Wires

   

 

C-Face Motors

  4 

2500-2307 

1/2 HP, 115V, 1 Phase

   

2500-2308 

1/2 HP, 208/230V, 1 Phase

   

2500-2309 

3/4 HP, 115V, 1 Phase

   

2500-2310 

3/4 HP, 208/230V, 1 Phase

   

2500-2311 

1 HP, 115V, 1 Phase

   

2500-2312 

1 HP, 208/230V, 1 Phase

   

2500-2313 

1/2 HP, 208/230/460V, 3 Phase

   

2500-2314 

3/4 HP, 208/230/460V, 3 Phase

   

2500-2315 

1 HP, 208/230/460V, 3 Phase

   

 

Capacitors

 

 

2500-2336 

Capacitor for 2500-2307 Motor

   

2500-2337 

Capacitor for 2500-2308 Motor

   

2500-1926 

Capacitor #1 for 2500-2309 Motor

   

2500-1930 

Capacitor #2 for 2500-2309 Motor

   

2500-1931 

Capacitor for 2500-2310 Motor

   

2500-2338 

Capacitor for 2500-2311 Motor

   

2500-1932 

Capacitor for 2500-2312 Motor

Summary of Contents for GSLG-A

Page 1: ...L325 COMPLIANCE REQUIRES THE USE OF CONTACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMATIC OR REMOTELY CONTROLLED GATE OPERATORS USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 4...

Page 2: ...tion 11 Onboard L E D Indicator Descriptions 12 Important Notes for Installation of Master Slave Applications 13 Surge Protector Instructions 13 Control and Accessory Connection Illustrations 14 17 IL...

Page 3: ...gate does not seem to operate properly it may affect the operator performance or greatly shorten the life of the unit The gate should be designed so that airflow through the fabric is ample to prevent...

Page 4: ...9 for details of this connection as well as dip switch selection Note The SHIELD wire should be connected in both the master and slave operators e s a h P 3 g n i r i W r e w o P s t l o V P H e c n...

Page 5: ...here are six 3 16 side plates which should be mounted on the outside top and bottom of the cabinet two 3 16 side plates which go on the top inside and two 1 2 side plates which should be mounted on th...

Page 6: ...idler over the drive sprocket and then under the last idler Make sure you feed most of the chain through the sprockets for attaching to the back end of the gate Assemble the other gate bracket on the...

Page 7: ...good working condition One person should be able to move the gate by hand Be certain the gate moves freely and without binding throughout its travel Torque limiters are set light at the factory and mu...

Page 8: ...operator after the limit switch is tripped Once the gate is in this position adjust the open limit nut until it activates the limit switch for open LSO 1 Press down on the detent plate and rotate the...

Page 9: ...of obstructions while running in the closed direction Master Slave Connection Block This terminal block is used in conjunction with two operators to configure two gates to open and close together Dip...

Page 10: ...ain prior to reaching a limit the gate will stop again and this time will sound the emergency alarm and lock out 4 51 CLOSE This function works exactly like the OPEN OBSTRUCTION except that it will on...

Page 11: ...otentiometer higher by 1 1 2 turns for all 115 Volt AC and 24 Volt DC operators and by 3 4 of a turn higher for all 230 Volt AC operators Additional fine adjustment by 1 4 turns may be necessary to el...

Page 12: ...tor wired to the safety loop terminals SHADOW LOOP This indicator is lit when a shadow hold open signal is present This signal is generated by a loop detector wired to the shadow loop terminals This i...

Page 13: ...nd Lock Release Three Second Pre Start Warning Right Left Hand Selections SURGE PROTECTOR INSTRUCTIONS The optional surge protector should be connected to any inputs that have an accessory connected t...

Page 14: ...GSLG A OPERATOR INSTALLATION GUIDE 14 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 15: ...GSLG A OPERATOR INSTALLATION GUIDE 15 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 16: ...GSLG A OPERATOR INSTALLATION GUIDE 16 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 17: ...GSLG A OPERATOR INSTALLATION GUIDE 17 CONTROL and ACCESSORY CONNECTION ILLUSTRATIONS...

Page 18: ...GSLG A OPERATOR INSTALLATION GUIDE 18 LOOP LAYOUT ILLUSTRATION Refer to Connection Descriptions on page 10 and Loop Accessory Connections on page 17 for details...

Page 19: ...GSLG A OPERATOR INSTALLATION GUIDE 19 EDGE LAYOUT ILLUSTRATION 1 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Page 20: ...GSLG A OPERATOR INSTALLATION GUIDE 20 EDGE LAYOUT ILLUSTRATION 2 Refer to Connection Descriptions on page 10 and Contact Edge Connections on page 16 for details...

Page 21: ...GSLG A OPERATOR INSTALLATION GUIDE 21 PHOTO EYE ILLUSTRATION Refer to Connection Descriptions on page 10 and Photo Eye Connections on page 16 for details...

Page 22: ...GSLG A OPERATOR INSTALLATION GUIDE 22 PICKET GATE ILLUSTRATION Refer to Connection Descriptions on page 10 and Accessory Connections on pages 14 17 for additional details...

Page 23: ...GSLG A OPERATOR INSTALLATION GUIDE 23 TRACK GATE ILLUSTRATION...

Page 24: ...rent sensing set too low Make sure the gate moves freely through its entire travel before ad justing the current sensing B The maximum run timer may have counted down and expired This can be caused by...

Page 25: ...GSLG A OPERATOR INSTALLATION GUIDE 25 MODEL GSLG A MECHANICAL PARTS EXPLODED VIEW...

Page 26: ...s 2500 034 Power Switch only REF NO PART NO DESCRIPTION 46 2100 1756 Mounting Plate 47 2100 1781 Accessory Shelf for single phase models only 33 2400 308 Fender Washer 3 8 34 2400 017 Flat Washer 3 8...

Page 27: ...y 10 2510 249 Input Wire Harness Assembly 11 2510 250 Output Wire Harness Assembly 12 2510 261 Control Box Motor Harness Assembly 13 2500 071 Terminal Strip 16 141 14 2500 212 Transformer 115 24VAC 40...

Page 28: ...0 268 Control Board only 10 2500 1980 3 Phase Motor Board 11 2500 1966 2 Amp Fuse for Control Board 12 2500 1975 3 Amp Fuse for Control Board 13 2510 253 Limit Switch Harness REF NO PART NO DESCRIPTIO...

Page 29: ...ar the source Laboratory samples should be handled in a fume hood Provide mechanical ventilation of confined spaces HANDLING STORAGE AND SHIPPING Keep containers closed Handle and open containers with...

Page 30: ...lace as necessary Check for proper tension and adjust if required Check all pulley setscrews for tightness and tighten if necessary 3 For operators with internal chain drives inspect chain and sprocke...

Page 31: ...GSLG A OPERATOR INSTALLATION GUIDE 31 This page intentionally left blank...

Page 32: ...d that these signs must remain at all times 8 Controls intended for user activation are located at least six feet 6 away from any mov ing part of the gate and where the user is prevented from reaching...

Reviews: