Power, Battery, & Ground Wiring
Power Wiring
✦
NOTE:
DO NOT APPLY POWE
R
UNTIL THE IN
S
TALLATION I
S
COMPLETE. TU
R
N MA
S
TE
R
POWE
R
S
WITCH OFF
B
EFO
R
E
WI
R
IN
G
.
1. Route two wires between the AE1000Plus and the power
transformer.
• For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt
insulated wire.
• For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt
insulated wire.
2. Connect the wires to the transformer. Connect the other end of the
wires to the AE1000Plus
AC1
&
AC2
terminals.
Backup Battery / Uninterruptable Power Supply
Use of battery backup is optional. It will allow the AE1000Plus to operate
for short periods of time without AC power. The door or gate access
device must use some type of battery backup of its own for the entire
system to be functional.
A backup battery will not fi t into the AE1000Plus case. Protect the backup
battery inside a rain-tight NEMA enclosure suitable for the installation.
✦
NOTE:
A backup battery is not required to maintain the
AE1000Plus clock/calendar and programming memory during
power outages.
1. Route two wires between the AE1000Plus and the backup battery.
2. Connect the Battery positive to the AE1000Plus
DC+
terminal and
the negative to the
DC-
terminal.
✦
NOTE:
The AE1000Plus does not supply battery charging
current. An external battery charger will be required to maintain the
battery.
Earth Ground
For the best ground, use size 12 gauge solid wire or larger to connect the
to an 8-foot copper ground rod. Locate the ground rod next to the Power
and Telephone company rods and bond the rods together with a new
clamp. Do not disturb the clamps installed by the Power or Telephone
Company. Alternately, connect to a metallic cold water pipe for the earth
ground.
1. Connect the wire from the earth ground to the AE1000Plus
EARTH
G
ROUND STUD
.
RS-232 Port
A modular connector is provided for the bi-directional 38.4K baud
RS-232 port. The AE1000Plus’s RS-232 port connects to a personal
computer’s COM port. System programming can be performed locally
with a computer connected to the RS-232 port.
16 VAC
35 VA
T
R
AN
S
FO
R
ME
R
EA
R
TH
G
R
OUND
S
TAKE
12 VOLT
B
ATTE
R
Y
POWER
TERMINALS
EA
R
TH
G
R
OUND
S
TUD
NOTE
:
THE OPTIONAL
B
ACKUP
B
ATTE
R
Y
WILL
R
EQUI
R
E AN
EXTE
R
NAL CHA
RG
E
R
DC
DC
AC
2
AC1
AE1000PLUS
RS-232 PORT
COMPUTER'S
COM PORT
LINEA
R
MODEL A
2
C
S
E
R
IAL COMPUTE
R
CA
B
LE
S
ET COMPUTE
R
COM PO
R
T
B
AUD
R
ATE TO
38
,400
B
P
S
NOTE
:
USE A DB-25 TO DB-9 CABLE ADAPTER IF REQUIRED