LTC3558
3
3558f
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Battery Charger
V
CC
Input Supply Voltage
l
4.3
5.5
V
I
VCC
Battery Charger Quiescent Current
(Note 4)
Standby Mode, Charge Terminated
Suspend Mode, V
SUSP
= 5V
285
8.5
400
17
μA
μA
V
FLOAT
BAT Regulated Output Voltage
0°C ≤ T
A
≤ 85°C
4.179
4.165
4.200
4.200
4.221
4.235
V
V
I
CHG
Constant-Current Mode Charge
Current
HPWR = 1
HPWR = 0
l
440
84
460
92
500
100
mA
mA
I
BAT
Battery Drain Current
Standby Mode, Charger Terminated, EN1 = EN2 = 0
Shutdown, V
CC
< V
UVLO
, BAT = 4.2V, EN1 = EN2 = 0
Suspend Mode, SUSP = 5V, BAT = 4.2V, EN1 = EN2 = 0
V
CC
= 0V, EN1 = EN2 = 1, MODE = 1,
FB1 = FB2 = 0.85V, V
OUT2
= 3.6V
–3.5
–2.5
–1.5
–50
–7
–4
–3
–100
μA
μA
μA
μA
V
UVLO
Undervoltage Lockout Threshold
BAT = 3.5V, V
CC
Rising
3.85
4
4.125
V
Δ
V
UVLO
Undervoltage Lockout Hysteresis
BAT = 3.5V
200
mV
V
DUVLO
Differential Undervoltage Lockout
Threshold
BAT = 4.05V, (V
CC
– BAT) Falling
30
50
70
mV
Δ
V
DUVLO
Differential Undervoltage Lockout
Hysteresis
BAT = 4.05V
130
mV
V
PROG
PROG Pin Servo Voltage
HPWR = 1
HPWR = 0
BAT < V
TRKL
1.000
0.200
0.100
V
V
V
h
PROG
Ratio of I
BAT
to PROG Pin Current
800
mA/mA
I
TRKL
Trickle Charge Current
BAT < V
TRKL
36
46
56
mA
V
TRKL
Trickle Charge Threshold Voltage
BAT Rising
2.8
2.9
3
V
Δ
V
TRKL
Trickle Charge Hysteresis Voltage
100
mV
Δ
V
RECHRG
Recharge Battery Threshold Voltage
Threshold Voltage Relative to V
FLOAT
–75
–95
–115
mV
t
RECHRG
Recharge Comparator Filter Time
BAT Falling
1.7
ms
t
TERM
Safety Timer Termination Period
BAT = V
FLOAT
3.5
4
4.5
Hour
t
BADBAT
Bad Battery Termination Time
BAT < V
TRKL
0.4
0.5
0.6
Hour
h
C/10
End-of-Charge Indication Current Ratio (Note 5)
0.085
0.1
0.11
mA/mA
t
C/10
End-of-Charge Comparator Filter Time
I
BAT
Falling
2.2
ms
R
ON(CHG)
Battery Charger Power FET On-
Resistance (Between V
CC
and BAT)
I
BAT
= 190mA
500
m
Ω
T
LIM
Junction Temperature in Constant
Temperature Mode
105
°C
NTC
V
COLD
Cold Temperature Fault Threshold
Voltage
Rising NTC Voltage
Hysteresis
75
76.5
1.6
78
%V
CC
%V
CC
V
HOT
Hot Temperature Fault Threshold
Voltage
Falling NTC Voltage
Hysteresis
33.4
34.9
1.6
36.4
%V
CC
%V
CC
V
DIS
NTC Disable Threshold Voltage
Falling NTC Voltage
Hysteresis
l
0.7
1.7
50
2.7
%V
CC
mV
I
NTC
NTC Leakage Current
V
NTC
= V
CC
= 5V
–1
1
μA
ELECTRICAL CHARACTERISTICS
The
l
denotes specifi cations that apply over the full operating temperature
range, otherwise specifi cations are at T
A
= 25°C. V
CC
= 5V, BAT = PV
IN1
= PV
IN2
= 3.6V, R
PROG
= 1.74k, unless otherwise noted.