LTC3350
37
3350fc
For more information
www.linear.com/LTC3350
regisTer DescripTions
mon_status
(0x1C)
Monitor Status: This register provides real time status information about the state of the monitoring system. Each bit is active high.
BIT(S)
BIT NAME
DESCRIPTION
0
mon_capesr_active
Capacitance/ESR measurement is in progress
1
mon_capesr_scheduled
Waiting programmed time to begin a capacitance/ESR measurement
2
mon_capesr_pending
Waiting for satisfactory conditions to begin a capacitance/ESR measurement
3
mon_cap_done
Capacitance measurement has completed
4
mon_esr_done
ESR Measurement has completed
5
mon_cap_failed
The last attempted capacitance measurement was unable to complete
6
mon_esr_failed
The last attempted ESR measurement was unable to complete
7
–
Reserved
8
mon_power_failed
This bit is set when V
IN
falls below the PFI threshold or the charger is unable to
charge. It is cleared only when power returns and the charger is able to charge.
9
mon_power_returned
This bit is set when the input is above the PFI threshold and the charger is able to
charge. It is cleared only when mon_power_failed is set.
15:10
–
Reserved
alarm_reg
(0x1D)
Alarms Register: A one in any bit in the register indicates its respective alarm has triggered. All bits are active high.
BIT(S)
BIT NAME
DESCRIPTION
0
alarm_cap_uv
Capacitor undervoltage alarm
1
alarm_cap_ov
Capacitor overvoltage alarm
2
alarm_gpi_uv
GPI undervoltage alarm
3
alarm_gpi_ov
GPI overvoltage alarm
4
alarm_vin_uv
V
IN
undervoltage alarm
5
alarm_vin_ov
V
IN
overvoltage alarm
6
alarm_vcap_uv
V
CAP
undervoltage alarm
7
alarm_vcap_ov
V
CAP
overvoltage alarm
8
alarm_vout_uv
V
OUT
undervoltage alarm
9
alarm_vout_ov
V
OUT
overvoltage alarm
10
alarm_iin_oc
Input overcurrent alarm
11
alarm_ichg_uc
Charge undercurrent alarm
12
alarm_dtemp_cold
Die temperature cold alarm
13
alarm_dtemp_hot
Die temperature hot alarm
14
alarm_esr_hi
ESR high alarm
15
alarm_cap_lo
Capacitance low alarm