If both the Control and AES67 ports will be used, they must be in different subnets. In-band control
is available using the AES67 port.
If only one port will be used, set the unused port to “Static IP” with an IP Address of 0.0.0.0, a
Subnet Mask of 0.0.0.1, and a Gateway of 0.0.0.0.
To set a fixed IP address for the Control port:
Press the Right button once to show the Information screen and once more to navigate to the IP
Configuration (Control) screen
Press the Down button to highlight “Edit”
Press the OK button to highlight “Use DHCP”
Press the Right button to highlight “Yes”
Press the Up/Down buttons to select “No”
Press the Left button to highlight “DHCP” again
Press the Down button to highlight “Address”
Press the Right button to move to the first digit of the IP address
Use the Up/Down buttons to change the value
Use the Right/Left buttons to select another digit to edit
When finished editing the Address field, press the Right/Left buttons to highlight “Address” again
Press the Down button to navigate to the “Netmask” field, following the instructions above for entering
the value
When finished editing the Netmask field, press the Right/Left buttons to highlight “Netmask” again
Press the Down button to navigate to the “Gateway” field, following the instructions above for entering
the value
When finished editing the Gateway field, press the Right/Left buttons to highlight “Gateway” again
Press the Down button to highlight “Update”
Verify the information has been entered correctly and press the OK button to save the new values
If you notice incorrect information and need to start over, use the Right button to highlight “Cancel” followed