![Linear Acoustic UPMAX ISC Manual Download Page 12](http://html1.mh-extra.com/html/linear-acoustic/upmax-isc/upmax-isc_manual_1922077012.webp)
Information screen
IP Configuration Screen
Another press of the Right button brings you to the IP Configuration screen for the Control port.
IMPORTANT: The Control and AES67 Ethernet connections both require 1000BASE-T (Gigabit)
switch ports in order to work properly.
If both the Control and AES67 ports will be used, they must be in different subnets. In-band control
is available using the AES67 port.
If only one port will be used, set the unused port to “Static IP” with an IP Address of 0.0.0.0, a
Subnet Mask of 0.0.0.1, and a Gateway of 0.0.0.0.
By default, the UPMAX ISC will automatically obtain an IP address from a DHCP server which will suffice to
provide initial remote access to the unit for configuration purposes. A fixed IP address will be preferred in
most cases and can be set as follows:
Press the OK button to highlight “Edit”
Press OK again to highlight “Use DHCP”
Press the Right button to highlight “Yes”
Press the Up/Down button to “No"
Press the Left button to highlight the “Static IP Address” fields
Press the Down button to highlight “Address”
Press the Right button to move to the first digit of the IP address
Use the Up/Down buttons to change the selection
Press the Right/Left buttons to select another digit to edit
When finished editing the address field, press the Right or Left button to return to “Address”
Press the Down button to navigate to the Netmask and Gateway fields
Repeat the above steps to edit the Netmask and Gateway fields; note that the gateway may be set to
000.000.000.000 if no gateway is required
After the gateway is set, press the Left button to highlight “Gateway”
Press the Down button to highlight “Update”