![Linear Acoustic AERO.100 User Manual Download Page 40](http://html1.mh-extra.com/html/linear-acoustic/aero-100/aero-100_user-manual_1922090040.webp)
AERO.100 User Guide
©2016 TLS Corp. ALL RIGHTS RESERVED
Oct 2016
Page 39
Figure 4-13
Settings for the program-specific ITU meter
The integration time of the 3 bar graph meters can be chosen as well as the integration time of
the digital readout. The integration of the digital readout can also be manually controlled to
measure specific programs or over specific time periods.
Note that the meter settings do not affect the loudness log readings.
Remember that the meter setup for each Instance is independent. To see both instances at the
same time two NfRemote sessions can be opened on the same PC at the same time. One
session can view Instance 1 and the second can view Instance 2.
4.10
4.10
4.10
4.10
Configuring
Configuring
Configuring
Configuring I/O
I/O
I/O
I/O
4.10.1
4.10.1
4.10.1
4.10.1
SDI Source
SDI Source
SDI Source
SDI Source
Connect your SDI program to the AERO SDI Input. If the power is off or the unit is starting the
bypass relays connect the SDI input to the SDI output.
The SDI audio
de-embedder is always active
so any of the SDI embedded audio pairs can be
processed and the audio, including Dolby encoded audio, can be sent to any of the AES digital
audio outputs.
If SDI embedding is NOT enabled then all of the SDI embedded audio channels in the SDI source
are passed to the SDI output.
If SDI embedding is enabled then any of the following signals can be routed to any SDI
embedded output pair.