Linea CLHS Series Camera
Appendix A: GenICam Commands
•
53
I/O Control Category
The camera’s I/O controls, as shown by CamExpert, group features used to configure external
inputs and acquisition actions based on those inputs, plus camera output signals to other devices.
I/O Control Feature Descriptions
The following table describes these features along with their view attribute and minimum camera
firmware version required:
Display Name
Feature & Values
Description
Standard
& View
Trigger Selector
TriggerSelector
Displays the type of trigger to configure with the various
Trigger features. <RO>
Beginner
LineStart
LineStart Selects a trigger starting the capture of a single line.
Trigger Mode
TriggerMode
Controls the enable state of the selected trigger.
Beginner
Off
Off The selected trigger is turned off.
On
On The selected trigger is turned active.
Flat Field Category
The camera’s Flat Field controls, as shown by CamExpert, group features used to calibrate the
camera’s flat field correction coefficients. Parameters in black are user set in CamExpert or
programmable via an imaging application.
Flat Field Feature Descriptions
The following table describes these features along with their view attribute:
Display Name
Feature & Values
Description
Standard
& View
Mode
flatfieldCorrectionMode
Sets the mode for flat field correction.
DFNC
Beginner
Off
Off
Flat field correction is disabled.
On
On
Flat field correction is enabled.
Initialize
Initialize
Reset all FPN coefficients to 0 and all flat field
coefficients to 1.
Calibration Algorithm
flatfieldCorrectionAlgorithm
Selects the algorithm to use for calibration of flat
field coefficients.
DFNC
Beginner
Basic
Basic Direct calculation of coefficients based on average
line values and target value.
Low Pass Filter
LowPass A low pass filter is first applied to the average line
values before calculating the coefficients. Use this
algorithm if the calibration target is not uniformly
white or it is not possible to defocus the image.
CalibrationTarget
flatfieldCalibrationTarget
Sets the target pixel value for the gain (PRNU)
calibration. Ranges are:
8-bit output: 0-255
12-bit output: 0-4095
DFNC
Beginner
CalibrationSampleSize flatfieldCalibrationSampleSize
Sets the number of line to average during a flat
field calibration.
DFNC
Beginner
2048
Lines_2048
Average 2048 lines.
4096
Lines_4096
Average 4096 lines.