2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]
7
|
P a g e
LB-1000-OSW
User Manual
contamination/blemish on the fiber cable and connector with a fiber inspecting
microscope. Ensure the fiber optic connectors and jumper cables are clean.
6)
Ensure optical jumper connectors are matched properly to the device adapters. (i.e.
SC/APC to SC/APC). Using mismatched connectors will damage the connectors and
degrade system performance. Ensure that each fiber has a matching connector.
7)
Use an optical power meter to verify that the optical input power level to the Optical
Switch is within the specification (-22 to +22dBm for this Switch). You can now
connect the Optical fiber to the
OPT IN
connector(s) on the front panel.
8)
Also, you can now connect the Optical fiber to the
OPT OUT
connector on the front
panel. Use an optical power meter to verify that the optical output power level is
within the specification.
9)
Using the touch screen or web interface via LB-1000-CM the operating parameters
for the application module can be monitored and adjusted. Operating parameters
and adjustments on the LB-1000-OSW are explained in the Section 5.0.