2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]
9
|
P a g e
LB-1000-OSW
User Manual
A Low Limit + / -
Set the low threshold level for switching of channel A. Low limit threshold
determines the optical level when automatic switching occurs based on optical
input.
B Low Limit + / -
Set the low threshold level for switching of channel B. Low limit threshold
determines the optical level when automatic switching occurs based on optical
input.
Revert Control ON /
OFF
If Revert Control is ON, then the output will automatically switch to main input
channel (prior output channel) when main channel is back to normal operation.
If Revert Control is OFF, then the output doesn’t
automatically switch back to
main input channel even when the main channel is back to normal operation.
RF Switch ON / OFF
If RF Switch is ON, then automatic switching will occur not only because of
optical channel level, but also due to the RF status on the optical channel.
Whenever there is an alarm on RF State of the channel, switching is triggered.
If RF Switch is OFF, then automatic switching is only because of optical channel
status (RF status doesn’t play a part here).
RF A State
Shows the status of RF level on channel A. Important for RF switching.
RF B State
Shows the status of RF level on channel B. Important for RF switching.
Serial Number
Shows the module serial number
Hardware Version
Shows the hardware version
Firmware Version
Shows the firmware version
Temperature
Shows the current module temperature (°C)
Running Time
Shows the active run time of the module
Figure 5: LB-1000-OSW settings - Page 2