![Lincoln LMC 1 User Manual Download Page 23](http://html1.mh-extra.com/html/lincoln/lmc-1/lmc-1_user-manual_1917670023.webp)
Subject to modifications
User Manual
LMC 1
9.3EN-98001-A07
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Page 23 of 36
Two-line systems, continued
Operation, continued
Adapting the parameters
Â
Press and hold the “ENTER“ key and then press “MENU“
to open the configuration mode.
You can modify the count value of every parameter using
the “UP“ and “DOWN“ keys as below:
- Press briefly ……………………….…...
±
1 count value
- Keep pressed …………………………….
±
High speed
Default 0, 1, 2, 3, 4 or 5::
(see table on page 11)
Menu item * t–MO *, monitoring time
(Lubrication with monitored metering device)
Setting the monitoring time determines the time interval in
which the corresponding final pressure monitor has to be
acknowledged before a fault indication.
If a monitored metering device is present, a signal change
has to be completed before the end of a lubrication cycle
(full pulse).
Â
Press the “UP“ or “DOWN“ key to configure the monitoring
time.
- Section
1 sec. to 99 min. and 59 sec.
- Count value 1 sec
Â
Conclude the selection with the “ENTER“ key.
Continue with the
* t–PS *
menu item.
6001a02
NOTE
As the pause time is also restarted at the
start of the lubrication time, the following
setting value applies:
Pause time > Lubrication time
If the ratio is reversed, the fault indication
* E-PD * appears in the LMC 1 display (see
page 10).
Default 0, 1, 2, 3, 4 or 5:
(see table on page 11)
Menu item * t–PS *, pause time
The pause time determines the time interval that must
expire between two lubrication sequences.
Â
Press the “UP“ or “DOWN“ key to configure the pause
time.
- Section
1 min. to 99 h and 59 min.
- Count value 1 min.
Â
Conclude the selection with the “ENTER“ key.
Â
Press the “RUN“ key (> 2 sec.), to incorporate the
changes made to all menu items. Otherwise, after 30
seconds the program reverts back to the operating mode.
Â
If you want to change a menu item again, press the
“ENTER“ key. You will once more automatically arrive at
the start of the configuration mode.