Impinger I -–1000 Series Service Manual - International
75
Dip Switch
1
2
3
4
5
6
7
8
9
10
TYPE I
OFF
OFF
OFF
ON
OFF
OFF
TYPE II
OFF
OFF
OFF
OFF
OFF
OFF
TYPE III
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
NOTE: When on 50 HZ power, dip switch #2 must be "ON"
With power ON turn time and temperature cal. pot. fully counterclockwise.
Display should read: (Wait 15-20 seconds)
TYPE I 9:30 + 10 sec.475 + 10°F
TYPE II 9:20 + 10 sec. HHH
TYPE III 9:35 + 10 sec. 635 + 10°F
Turn time and temp. cal. pot. fully clockwise.
Display should read: (Wait 15-20 seconds)
TYPE I 10:20 + 10 sec. 615 + 10°F
TYPE II 10:10 + 10 sec. 475 + 10°F
TYPE III 10:20 + 10 sec. 475 + 10°F
Turn time pot. to 10:00 minutes and temp. pot. to 540°F.
Time reading 10:00 ± 5 seconds.
Temperature reading should be steady at 540°F + 10°F.
If these readings are not achieved, replace display.
NOTE:
After simulator test is completed, the oven Time/Temperature Display must be re-calibrated.
SWITCH REPLACEMENT (FAN, HEAT, CONVEYOR)
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove switch access cover.
4.
Depress the spring clips on the sides of the switch and push out.
5.
Remove wires from back of switch. Note wire number and location.
6.
Install new switch in reverse order and check.
SWITCH REPLACEMENT - (FAN SWITCH UPDATE)
INSTALLATION OF DOUBLE POLE FAN SWITCH #369260 IN PLACE OF SINGLE POLE
FAN SWITCH #350705
NOTE:
This change is not necessary for proper operation of oven nor is it
permissible to change under warranty. Should be changed only at
customer's request and their agreement to pay your bill.
ADVANTAGE:
Allows time/temp. display, in older models, to operate same as current
production models. Also allows locked time/temp. display (caused by
voltage surge, interruption or spike) to be reset by fan switch rather than
circuit breaker.
IDENTIFICATION:
To determine which fan switch you have, observe if temperature displays
stays on during cooling down. If it stays on , you have the single pole
switch. If it goes out as soon as fan switch is turned off you have the double
pole switch.
REPLACEMENT: Replace single pole switch # 350705.
Install double pole switch # 369260.
Disconnect lead indicated by # in proper diagram and reroute as shown.
Install jumper lead indicated by * in proper diagram.
Reapply all other leads as removed.
Summary of Contents for Impinger 1002
Page 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Page 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Page 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Page 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Page 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Page 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Page 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Page 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Page 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Page 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Page 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Page 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Page 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Page 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Page 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Page 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Page 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Page 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Page 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Page 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Page 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Page 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Page 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Page 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Page 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Page 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Page 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Page 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Page 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Page 112: ...Impinger I 1000 Series Service Manual International 112...