Impinger I -–1000 Series Service Manual - International
47
Incoming Power Supply
Check circuit breakers, reset if required. Call the
Power Co. if needed.
Fuse Transformer
Check, replace if necessary.
Fuseholder
Check, replace if necessary.
Cooling Fan Thermostat
Check the cooling fan thermostat (Thermostat
closes at 120°F and opens at 100°F). With the
cooling fan thermostat pre-heated, check for
continuity. If switch is open, replace.
No automatic control
box cooling
Cooling Fan
120 VAC should now be at this motor. If voltage is
present, check motor for shorts, opens, or grounds.
WITH POWER OFF: check for locked rotor.
Cooling fan continues
to run after 20 minute
cool down
Cooling Fan Thermostat
Thermostat is normally open and may have closed
if control box temperature is 120°F or above.
Gas Supply
Check for adequate gas supply to oven.
Manual Gas Shut-off Valve
Check to see that manual shut-off valve is open.
Fan Switch Main Oven Fan
Check to see that the fan switch is on. Check if
main oven fan is operating. If not, refer to "Oven
fan will not run."
Oven Start Relay
Check for contacts to close.
Burner Switch
Check for 220 VAC to neutral on both sides of
switch.
Air Pressure Switch
Check for 220 VAC on both sides of switch. If
voltage present on one side only, check for air tube
blockage. Adjust air switch. If above fails, replace
air pressure switch.
Gas Pressure Switch
Check for 220 VAC to neutral on both sides of
switch. If voltage is present on one side of switch
only, check the following. Check for proper gas
pressure supply to gas valve.(Marked on oven spec
plate). Check for proper adjustment of gas pressure
switch. Should be set at 8.8 for Nat., 23 for L.P.
Check gas filter in gas valve for blockage or
damage. (See Adjustment Section for location). If
the above checks okay, but switch still not closed,
replace gas valve.
Hi-Limit Thermostat
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will not
hold for maximum oven temperature, and oven is
not exceeding temperature dial setting, check for
proper location of capillary bulb in its spring holder.
If above checks okay, replace hi-limit thermostat.
Ignition Control
Check for 220 VAC supply to ignition control at pin
#1 and neutral. If voltage is not present, retrace
wiring back to hi-limit thermostat. Check for 220
VAC at pin #6 to neutral.(Power to burner motor). If
voltage is present, proceed. If no voltage is
present, wait 30 seconds and check reset button. If
above fails, replace ignition control.
Oven will not heat
Burner Blower Motor
Check for 220 VAC supply to burner blower motor.
WITH POWER OFF: turn blower wheel to check for
locked rotor. If 220 VAC is present and motor does
not run, replace motor.
Burner Blower Motor Air
Pressure Switch
Check for 220 VAC switching to pin "N.O." as the
air pressure switch closes. For Honeywell ignition
control only, connect a temporary jumper wire (for
testing purposes only) from pin "C" to pin "N.O." on
ignition control (to bypass air switch). Check for air
tube blockage or misalignment, adjust air pressure
switch. If the above fails, replace air pressure
switch.
Summary of Contents for Impinger 1002
Page 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Page 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Page 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Page 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Page 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Page 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Page 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Page 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Page 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Page 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Page 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Page 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Page 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Page 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Page 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Page 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Page 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Page 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Page 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Page 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Page 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Page 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Page 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Page 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Page 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Page 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Page 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Page 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Page 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Page 112: ...Impinger I 1000 Series Service Manual International 112...