Impinger I -–1000 Series Service Manual - International
49
Temperature Control
Check for 120 VAC across L1 and L2 on
temperature control board. If no voltage is present,
retrace wiring back to power supply. Turn the
temperature adjustment knob to the maximum
temperature position and check for 120 VAC at the
load terminal to neutral. If 120 VAC is not present,
proceed as follows: If 120 VAC is present and unit
is not heating, see "Solenoid Valve."
Thermocouple Probe
Remove thermocouple leads from the temperature
control board and measure the millivolt output of
these leads. Refer to chart on page 59 for proper
readings. If the thermocouple probe checks good,
then the problem is usually with the temperature
control board.
Solenoid Valve
If output voltage is present at temperature control
board, check for voltage at solenoid valve. If
voltage is present, listen for valve to open and
close. Also check for opens, shorts in coil. Replace
as needed.
Temperature Control
Check for 120 VAC across L1 and L2 on
temperature control board. If no voltage is present,
retrace wiring back to power supply. Turn the
temperature adjustment knob to the maximum
temperature position and check for 220 VAC at the
load terminal to neutral. If 220 VAC is not present,
proceed as follows: If 220 VAC is present, and unit
is not heating, see "Flame Monitor". Check for 220
VAC at terminal "COM" on temperature control
board. If no voltage is present, trace wiring back to
ignition control.
Thermocouple Probe
Remove thermocouple leads from the temperature
control board and measure the millivolt output of
these leads. Refer to chart on page 59 for proper
readings. If the thermocouple probe checks good,
replace temperature control.
Flame Monitor
Check for 220 VAC at terminal #1. If no voltage is
present, trace wiring back to temperature control.
Check for 220 VAC output at terminal #8. NOTE:
There is a delay of up to 2 seconds for 220 VAC
output at terminal #8. If there is no voltage output
at terminal #8, check the reset button. Replace
control as needed.
Relay, Main Burner
Check for 220 VAC at relay coil, if no voltage is
present, trace wiring back to flame monitor. Check
for 120 VAC to relay contacts. If no voltage is
present, trace wiring back to power supply. Check
to ensure contacts are closing. Replace relay as
needed.
Indicator light is on,
but no main flame
(1033-1034)
Valve, Temperature
Regulation
Check for 120 VAC at valve, if no voltage is
present, trace wiring back to relay. If voltage is
present, listen for valve to open and close. Check
for opens or shorts in coil. Replace as needed.
Summary of Contents for Impinger 1002
Page 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Page 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Page 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Page 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Page 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Page 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Page 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Page 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Page 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Page 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Page 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Page 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Page 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Page 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Page 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Page 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Page 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Page 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Page 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Page 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Page 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Page 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Page 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Page 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Page 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Page 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Page 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Page 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Page 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Page 112: ...Impinger I 1000 Series Service Manual International 112...