Subject to modifications
User Manual
Operation Instructions
2.1A-39002-B07
Page 7 of 24
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Description
6132b05
Fig. 1
Components of the Lubrication Pump HTL -101
1 - Follower piston, cartridge full
2 - Cartridge
3 - Lubricant outlet, G ¼
4 - Lubrication hydraulic fitting, for manual lubrication
(M = 14 Nm ±5%)
5 -
Pump element
6 -
Housing
7 - Pressure relief valve 120 bar (M = 12 Nm ±5%)
8 - Housing cover
9 - Eccentric (cam)shaft
10 - Low-level position (window) of the follower piston,
cartridge empty
11 - Fastening holes for M 14 bolts
12 - Cover cap for the regulating throttle valve
The Pump Model HTL 101
is a hydraulically driven grease pump for the lubrication of
hydraulic hammers or other units with an available hy-
draulic circuit.
is compact and can therefore be fitted directly to the
hammer or other units. Together with the carrier it forms a
complete assembly.
is driven by the hydraulic system of the carrier .
continuously delivers lubricant to the lubrication point
while the hydraulic unit is in operation and stops when the
hydraulic flow stops. The lubricant quantity is adjustable
via the regulating throttle valve (see Fig. 3, page 8).
is equipped with a visual lubricant level indicator by
means of the follower plate of the cartridge. If the follower
plate is located in the low-level position of the cartridge
(item 10, Fig. 1), the cartridge must be replaced.
is protected by means of a 120 bar pressure relief valve
(item 7, Fig. 1) (cartridge).
is equipped with an easy-to exchange pump element
(item 5, Fig. 1).
is equipped with a lubrication hydraulic fitting (item 4, Fig.
1) for manual lubrication override (e.g. if the hydraulic sys-
tem fails to operate).
does not require supplementary directional valve.
has three different outlets (items 3 & 7, Fig.1) for the indi-
vidual grease supply connection of the hammer (unit).
6001a02
NOTE
If the lower lubricant outlet connection is
used (item 7, Fig. 1), the outlet fitting and
the pressure relief valve must be ex-
changed.
If the rear outlet is used, the outlet fitting
and closure plug must be exchanged.