58. To remove lower plunger, use special tool provided in kit
276275.
59. With the tool in place, insert the pin from tool kit (276275)
through the tool and into the plunger outlet hole.
60. Remove plunger (Item 19). (Reassembly torque: 100-110
in. lbs. (11.3 - 12.4 Nm).) (Reassembly recommendations: use
Loctite 242 or equivalent on plunger threads).
61. Push out check ball (Item 18) and check spring (Item 17).
62. Clamp crank rod/eccentric assembly (Items 1-7) in vise.
63. Loosen flat head screw (Item 1). (Reassembly torque: 100-
110 in. lbs. (11.3 - 12.4 Nm).)
64. Remove flat head screws (Item 1). (Reassembly recom-
mendation: use Loctite 242 on screw threads).