manualshive.com logo in svg
background image

www.regulus.eu

CSE 

TC 

W iP

WM MFB

CSE TC W iPWM MFB

EN

Installation and Operation Manual

CSE TC W iPWM MFB PUMP STATION 

 

Содержание CSE TC W iPWM MFB

Страница 1: ...www regulus eu CSE TC W iPWM MFB CSE TC W iPWM MFB EN Installation and Operation Manual CSE TC W iPWM MFB PUMP STATION ...

Страница 2: ... 8 iPWM1 130mm ball valve w filter and magnet thermometer insulation Main features Application heat pump circuit Description consists of PARA 25 8 iPWM1 130 mm pump 2 ball valves one with strainer and magnet thermometer insulation Working fluid water water glycol mixture max 1 1 or water glycerine mixture max 2 1 Installation return pipe of a heat pump 100 mm min pipe centre distance from wall Cod...

Страница 3: ...icated by LEDs directly on the pump The pump can send the current flow rate electronically to an external controller The controller needs to be equipped with an iPWM read input and a flow rate calculation function The high efficiency circulation pumps of the PARA iPWM1 series are used exclusively for the circula tion of liquids in hot water heating systems Ope rating the pump in other systems or i...

Страница 4: ... 3 Pump Wiring The pump must be wired disconnected by a qualified person in compliance with EN 50110 1 Wilo PARA 25 8 iPWM1 pump wiring L brown N blue PE yellow green PWM in brown PWM GND blue iPWM out black 1 POWER SUPPLY 1 230V 50 Hz 2 CONTROL iPWM ...

Страница 5: ...rature 0 95 C Max static pressure 10 bar Max head 8 4 m 4 5 FAULTS AND THEIR REASONS The LED light signals a defect The pump will switch off depending on the defect type and try to restart If the fault cannot be rectified contact a qualified technician GREEN IS LIT RED IS LIT FLASHING RED FLASHING RED AND GREEN 1 pump is running in trouble free operation 1 rotor is blocked 2 electric motor winding...

Страница 6: ... 6 4 6 Performace curves for Wilo Para 25 8 iPWM1 pump ...

Страница 7: ...se by 90 Fig 1 2 Unscrew the lid with magnet manually and take out the strainer Fig 2 3 3 Remove impurities from the strainer and magnet 4 Return the clean strainer back to its place and screw on the lid with magnet 3 Open the ball valve by turning the lever counter clockwise by 90 Fig 4 fig 1 fig 2 fig 3 fig 4 ...

Страница 8: ... 2020 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o E mail sales regulus eu Web www regulus eu v1 0 02 2020 ...

Отзывы: