Page Number - 4
Form 404372
Electric Operated Centro-Matic Pump P653S
Safety Instructions
Appropriate Use
The electric Centro-Matic pump P653S has been designed for
the automatic lubrication of commercial vehicles, industrial,
construction and agricultural machines and wind power plants.
The P653S pump has been designed for intermittent opera-
tion and is not suitable for continuous operation. The pump is
capable of supplying lubricants up to NLGI # 2 grades. (see
pages 32-34 for list of recommended greases).
Misuse
Any use of the P653S pump that is not expressly mentioned
in this User Manual will be regarded as misuse. If the P653S
pump is used or operated in a manner other than specified,
any claim for warranty or liability will be null and void.
CAUTION !
If personal injury or material damage oc-
curs as a result of inappropriate operation,
(e.g. if the safety instructions are ignored
or resulting from an incorrect installation
of the P653S pump), no claims or legal
actions may be taken against Lincoln
Industrial
Exclusion of Liability
The manufacturer of the P653S pump will not accept any li-
ability for damages caused by:
•
a lack of lubricant due to an irregular refilling of the pump
•
the use of contaminated lubricants
•
the use of greases which are not or only conditionally
pumpable by P653S pump
•
inadequate disposal of used or contaminated lubricants
as well as of components that have been in touch with
lubricant
•
unauthorized modification of the system components
•
the use of unapproved parts
•
operation without adhering to the minimum pause time
and respectively the maximum lubrication time (see chap-
ter “Technical Data“)
Regulations for Prevention of Accidents
To prevent accidents, observe all city, state and federal safety
regulation of the country in which the product will be used.
General Safety Instructions
•
Pump P653S is designed for safe operation.
•
Incorrect use may result in bearing damage caused by
poor or excessive lubrication.
•
P653S pump with follower can be mounted vertically,
horizontally or upside down.
•
Pump without the follower should be mounted vertically
upright only.
•
Unauthorized modifications or changes to an installed sys-
tem are not admissible. Any modification of the pump must
be subject to prior authorization by manufacturer.
•
Install the components of the P653S pump in such way
that operator can always see the low-level position of the
pump reservoir.
•
Each time the reservoir has been refilled, make sure that
no air has been trapped under the follower and pump is
pumping lubricant.
Operation, Maintenance and Repair
WARNING!
Before carrying out any maintenance or
repair on the P653S pump, make sure
that all lubrication lines of the carrier unit
are depressurized.
Repair
Repair should only be performed by authorized and instructed
personnel who are familiar with the instructions.
Operation/Maintenance
Pumps P653S:
•
Must be refilled at regular intervals with clean lubricant
recommended by the manufacturer without air entrap-
ments under follower plate.
•
Operate automatically. However, a regular check (approx.
every 2 days) should be made to ensure that lubricant is
pumped to all lubrication points.
Disposal
Dispose of used or contaminated lubricants as well as of parts
that were in touch with lubricant according to the legal regu-
lations pertaining to environmental protection. Make sure to
observe the safety data sheets of the lubricants used.
████████████████████████████████████████████████████████████████████████████████████████████
Summary of Contents for Centro-Matic P653S
Page 38: ...Page Number 38 Form 404372 Electric Operated Centro Matic Pump P653S...
Page 40: ...Page Number 40 Form 404372 Electric Operated Centro Matic Pump P653S...
Page 43: ...Page Number 43 Form 404372 Electric Operated Centro Matic Pump P653S Pump with Follower...
Page 46: ...Page Number 46 Form 404372 Electric Operated Centro Matic Pump P653S PUMP WITHOUT FOLLOWER...
Page 48: ...Page Number 48 Form 404372 Electric Operated Centro Matic Pump P653S...