Page Number - 23
Form 404372
Electric Operated Centro-Matic Pump P653S
Programming Mode: Pump with Pressure Transducer
Display
Press
IMPORTANT
The P7 programming will only appear if you
have a pump that has an internal pressure
transducer.
P7: Programs the setting of where the internal pressure trans-
ducer will close. This is the maximum pressure that the pump
can reach. Factory setting is 3,500 psi.
Press button to change value.
Reading x 100 = Transducer setting in psi
35 x 100 = 3500 psi.
This setting is adjustable from 1400 psi to 4600 psi in 100 psi
increments.
IMPORTANT
The P8 programming parameter will only
appear if you have a pump that has an
external pressure transducer connected.
P8: Programs the setting of where the external pressure trans-
ducer will open. The opening point (vent pressure) is adjust-
able from 200 psi to 1,000 psi in 100 psi increments. Factory
set opening point (vent pressure) is 900 psi. The closing point
of the external pressure transducer is fixed in software at 2500
psi.
Press button to change value.
Reading x 100 = Transducer setting in psi
9 x 100 = 900 psi.
Complete Steps 1 through 6 of Pump with Pressure
switch
Step 7
Step 8
████████████████████████████████████████████████████████████████████████████████████████████
Summary of Contents for Centro-Matic P653S
Page 38: ...Page Number 38 Form 404372 Electric Operated Centro Matic Pump P653S...
Page 40: ...Page Number 40 Form 404372 Electric Operated Centro Matic Pump P653S...
Page 43: ...Page Number 43 Form 404372 Electric Operated Centro Matic Pump P653S Pump with Follower...
Page 46: ...Page Number 46 Form 404372 Electric Operated Centro Matic Pump P653S PUMP WITHOUT FOLLOWER...
Page 48: ...Page Number 48 Form 404372 Electric Operated Centro Matic Pump P653S...