HOW DOES THE SELF CLEANING LINCOLN CELL WORK?
To describe the operation simply, the Lincoln Chlorinator controls the
forward direction of the cell for a period of 12 hours.
It then stops for a short period before slowly ramping up to the set power
level in the reverse direction for a period of 12 hours. This reversing
process is repeated continually and assists greatly in reducing calcium
buildup in the cell.
When the Lincoln Chlorinator is reversing the direction of the cell, all “Menu
Operations” become inactive during the changeover period.
The Lincoln Chlorinator also monitors the power passed through the
cell when in forward or reverse direction. The “Dynamic Cell Balancing”
technology constantly tracks the power output to further assist in
eliminating scale build up and uneven cell wear.
Therefore, the cell is almost maintenance free.
Heavy bathing loads and excess suntan lotion can coat the cell and affect
chlorine production over an extended period and the cell may need a light
acid wash every six months.
CLEANING MIXTURE: 1 part pool acid to 10 parts water
NOTE: Excess acid will damage the cell.
HOW DO I MAINTAIN THE CELL?
If
a
t any time you fi nd it necessary to clean the cell please follow the
following steps:
1. Create a “cleaning mixture” in a container consisting of 1 part pool acid
to 10 parts water. DO NOT USE MORE ACID
2. Switch off the chlorinator power and unplug from power outlet.
3. Remove the cell from the housing by unscrewing the cell cap.
4. Place cell into container of cleaning mixture and leave for a few minutes
to dissolve scale build up. DO NOT SCRATCH OR SCRUB – This will
damage the coating and void the warranty.
5. If the scale build up does not dissolve after approxiametly 10 minutes,
create a new mixture and repeat the process.
6. Replace cell in housing and screw cap back on, ensuring that it has
been fi tted securely
7. Plug in Lincoln Chlorinator and switch power on.
SETTING THE TIMER
Enter the MAIN MENU by pressing the [MENU] button.
Use the [ ] and [ ]buttons to
navigate the menu until the arrow
indicates that you have reached
TIMER SETTINGS. Press the
[ENTER] button to enter
into the settings.
The TIMER SETTINGS can be programmed to turn the chlorinator ON or
OFF in one hour segments over the course of a 24 hour day.
CLEAR SEGMENT = OFF
The chlorinator will NOT operate
for that whole hour
FILLED SEGMENT = ON
The chlorinator will operate for that
whole hour
Use the [ ] and [ ] buttons to move the pointer to the desired segment.
Press the [ENTER] button to toggle
the corresponding segment either
ON or OFF.
To the left of the screen, the
time period relating to the segment
indicated by the pointer is displayed.
If you select the fi rst segment to be ON (as shown in the above example)
the chlorinator will turn on at 00:00 hours and switch off at 01:00 hours.
You can turn ON or OFF as many
one hour segments as you wish.
Press the [MENU] button to save
changes and return to the
MAIN MENU.
Press the [MENU] button once more to exit the MAIN MENU and return to
the MAIN OPERATING SCREEN.
Mode Select
Chlorine Output
TimerSettings
Pump Protection