Page 13
Page 10
Press the [MENU] button once more to exit the MAIN MENU and return to
the MAIN OPERATING SCREEN.
SYSTEM INFO
Enter the MAIN MENU by pressing the [MENU] button.
Use the [ ] and [ ] buttons to navigate the MAIN MENU until the arrow
indicates that you have reached SYSTEM INFO. Press the [ENTER] button
to enter the SYSTEM INFO display screen..
The SYSTEM INFO screen displays system information which is mainly of
use to the manufacturer and it’s service agents.
POWER CYCLES
The number of times the Chlorinator has had
power
removed and applied.
HOUR COUNTER
The total number of hours the Chlorinator has
operated.
CELL POLARITY
The polarity at which the electrolytic cell is
currently
working in.
‘+’ is forward and ‘-‘ is reverse.
FIRMWARE BUILD NO
: Denotes the fi rmware revision installed into the
chlorinator.
To exit the SYSTEM INFO display screen and return to the MAIN MENU
press the [MENU] button.
PUMP PROTECTION
Enter the MAIN MENU by pressing the [MENU] button.
Use the [ ] and [ ] buttons to
navigate the MAIN MENU until
the arrow indicates that you have
reached PUMP PROTECTION.
Press the [ENTER] button to enter
into the settings.
Press the [ ] or [ ] button
to toggle the PUMP PROTECTION
feature ON or OFF.
Press the [ENTER] button to save
the selection made and the arrow
pointer will move to the next line.
Press the [ ] and [ ] buttons to set the PUMP PROTECTION timeout
value to your desired setting. This value can range between 1 and 10
minutes.
Press the [ENTER] button to save your changes and return to the MAIN
MENU.
Press the [MENU] button once more to exit the MAIN MENU and return to
the MAIN OPERATING SCREEN.
PUMP PROTECTION when activated provides additional protection to the
pump in the case of a blockage or plumbing fault. PUMP PROTECTION
will prevent the pump from running dry for prolonged periods of time which
may cause undue wear or damage to the pumps seals. Once a PUMP FAIL
condition has arisen due to a blockage or plumbing fault, the chlorinator will
cease to operate for a period of one hour. If after an hour, the chlorinator is
still scheduled to run, it will start up again in the hope that remedial action
has been taken, or the condition which caused the PUMP FAIL condition
has cleared on it’s own accord.
Mode Select
Chlorine Output
TimerSettings
Pump Protection
On
Fail After 10 min
Power Cycles:1
Hour Counter:1
Cell Po
Firmware Build No
Cell Cleaning
Clock (Set Time)
Contrast (Adj)
System Info