OPERATION
B-22
B-22
VRTEX
TM
360
Reset Trip
Pressing
Reset Trip
zeroes out all items in the trip col-
umn. This allows an instructor to track VR material
savings over a certain time period.
Save to File
If a USB memory device is in the front of the unit,
selecting “save to file” saves a file with all of the current
Weldometer
TM
information. Once the file has saved,
the user can take the USB to a computer or printer to
print, email, copy, store or view the file.
Back
Pressing
Back
takes the user to the previous screen.
Tolerance Editor
Overview
The tolerance editor allows users to modify the system
default settings to fit their curriculum.
The
VRTEX
TM
360 ships with Lincoln “default” welding
parameters pre-installed. These default parameters
can be modified by the instructor to reflect a specific
welding application or technique. The welding parame-
ters that can be modified include:
- WFS range
- Voltage range
- Amperage range
- Gas mixture
- Gas flow rate
The technique parameters ideal range values can also
be modified:
- Position
- CTWD/Arc length
- Work angle
- Travel angle
- Travel Speed
TOLERANCES
CAUTION
Changing the settings in the tolerance editor will
dramatically affect how the system runs. Take care
in changing the settings of the tolerance editor as
not to reflect unrealistic welding situations.