FIGURE F.43 – VR GMAW/FCAW DEVICE LOCATION
VR GMAW/FCAW (MIG) DEVICE
REMOVAL AND REPLACEMENT PROCEDURE (continued)
REMOVAL PROCEDURE
1. Remove input power.
2. Perform the
Monitor and Pedestal Removal
Procedure
.
3. Perform the
Case Cover Removal Procedure
.
4. Locate the VR GMAW/FCAW Device. See
Figure F.43.
5. Using the 3/8” wrench, remove the two screws
holding the sheet metal strain relief to the front
panel.
See Figure F.44.
6. Locate the VGA cable splice (audio style con-
nector) and disconnect. See wiring diagram.
7. Disconnect VGA cable splice “Y-adapter”.
Remove cable ties as necessary.
TROUBLESHOOTING AND REPAIR