ANGLE OF OPERATION
To achieve optimum engine performance the VANTAGE
®
520 SD
should be run in a level position. The maximum angle of operation
for the Deutz engine is 15 degrees in all directions. When operating
the welder at an angle, provisions must be made for checking and
maintaining the oil level at the normal (FULL) oil capacity. Also the
effective fuel capacity will be slightly less than the specified 20
gal.(75.7 ltrs.) will be slightly less than the amount specified.
LIFTING
The VANTAGE
®
520 SD weighs approximately 1641 lbs. (744kg.)
with a full tank of fuel and 1526 lbs. (692kg) less fuel. A lift bail is
mounted to the machine and should always be used when lifting
the machine.
• Lift only with equipment of adequate lift-
ing capacity.
• Be sure machine is stable when lifting.
• Do not lift this machine using lift bale if it
is equipped with a heavy accessory such
as trailer or gas cylinder.
FALLING
• Do not lift machine if lift bale is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while
suspended from lift bale.
------------------------------------------------------------------
HIGH ALTITUDE OPERATION
At higher altitudes, output derating may be necessary. For maxi-
mum rating, derate the welder output in accordance with the guide-
lines in Table A.1 for this engine model from the manufacturer:
TABLE A.1 DEUTZ D 2.9 L4
ALTITUDE
MAXIMUM POWER
METERS
FEET
AVAILABLE (%)
0-750
0-2461
99
1000
3281
95
2000
6562
95
3000
9842
93
4000
13123
88
5000
16404
74
6000
19685
60
HIGH TEMPERATURE OPERATION
At temperatures above 104°F (40°C), output voltage derating may
be necessary. For maximum output current ratings, derate welder
voltage rating 2 volts for every 21°F (10°C) above 104°F (40°C).
Cold weather starting:
With a fully charged battery and OW40 oil, the engine should
start satisfactorily down to -20°F (-29°C). If the engine must be
frequently started at or below 0°F (-18°C) cold starting aids are
recommended. At temperatures below 23°F (-5°C) fuels in
accordance with ASTM S975 Grade 1D diesel fuel is recom-
mended. Allow the engine to idle for 3 to 5 minutes or until the
water temperature begins to rise before applying load to
switching to high idle.
Under no conditions should ether or other starting fluids be
used with this engine!
------------------------------------------------------------------
WARNING
WARNING
Summary of Contents for VANTAGE 520 SD
Page 8: ...8 NOTES VANTAGE 520 SD ...
Page 20: ...A 12 NOTES VANTAGE 520 SD ...
Page 49: ...F 3 CONNECTION DIAGRAMS VANTAGE 520 SD ...
Page 50: ...F 4 CONNECTION DIAGRAMS VANTAGE 520 SD ...
Page 51: ...F 5 CONNECTION DIAGRAMS VANTAGE 520 SD ...
Page 56: ...F 10 NOTES VANTAGE 520 SD ...