B-15
OPERATION
VANTAGE
®
520 SD
TABLE B.6 VANTAGE
®
520 SD DEUTZ Extension Cord Length Recommendations
Current
(Amps)
15
15
20
20
25
30
38
50
Voltage
(Volts)
120
240
120
240
240
240
240
240
Load
(Watts)
1800
3600
2400
4800
6000
7200
9000
12000
30
60
(9)
(18)
40
75
30
60
(12)
(23)
(9)
(18)
75
150
50
100
90
75
(23)
(46)
(15)
(30)
(27)
(23)
125
225
88
175
150
120
100
(38)
(69)
(27)
(53)
(46)
(37)
(30)
175
350
138
275
225
175
150
125
(53)
(107)
(42)
(84)
(69)
(53)
(46)
(38)
300
600
225
450
250
300
250
200
(91)
(183)
(69)
(137)
(76)
(91)
(76)
(61)
Maximum Allowable Cord Length in ft. (m) for Conductor Size
Conductor size is based on maximum 2.0% voltage drop.
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
TABLE B.5 VANTAGE
®
520 SD DEUTZ SIMULTANEOUS WELDING AND POWER LOADS
WELD
AMPS
0
100
200
300
400
up to 500
1 PHASE
WATTS
AMPS
11,000 46
11,000 46
8000 33
4700 20
1700 7
0 0
3 PHASE
WATTS
AMPS
17,000 41
15,400 37
13,000 31
9400 23
3400 8
0 0
BOTH 1 AND 3 PHASE
WATTS
AMPS
11,000
------
11,000
------
8000
------
4700 ------
1700 ------
0 0
PLUS
OR
OR
Summary of Contents for VANTAGE 520 SD
Page 8: ...8 NOTES VANTAGE 520 SD ...
Page 20: ...A 12 NOTES VANTAGE 520 SD ...
Page 49: ...F 3 CONNECTION DIAGRAMS VANTAGE 520 SD ...
Page 50: ...F 4 CONNECTION DIAGRAMS VANTAGE 520 SD ...
Page 51: ...F 5 CONNECTION DIAGRAMS VANTAGE 520 SD ...
Page 56: ...F 10 NOTES VANTAGE 520 SD ...