Section 3: Installation
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
3-17
Marking Plasma Gas Hose
1. Connect one end of the marking plasma gas hose to the marking plasma
outlet on the rear of the AGC.
2. Connect the other end of the marking plasma hose to the marking plasma
inlet on the 5-gang manifold.
Postflow Gas Hose
1. Connect one end of the postflow hose to the postflow outlet on the rear of the
AGC. Note that the postflow hose fittings have left hand threads.
2. Connect the other end of the postflow hose to the postflow inlet on the 5-gang
manifold.
Plasma Gas Hose
1. Connect on end of the plasma hose to the plasma outlet on the rear of the
AGC.
2. Connect the other end of the plasma hose to the plasma inlet on the 2-gang
manifold.
Shield Gas Hose
1. Connect one end of the shield hose to the shield outlet on the rear of the
AGC.
2. Connect the other end of the shield hose to the shield inlet on the 5-gang
manifold.
Preflow Gas Hose
1. Connect one end of the preflow hose to the preflow outlet on the rear of the
AGC. Note that the preflow hose fittings have left hand threads.
2. Connect the other end of the preflow hose to the preflow inlet on the 5-gang
manifold.
5-Gang Manifold Control Cable
1. Connect the 5-gang manifold control cable plug marked P15 to the 5-gang
manifold as shown.
2. Connect the 5-gang manifold control cable plug labeled P12 to the connector
labeled P12 on the rear of the power supply.
2-Gang Manifold Control Cable
1. Connect the 2-gang manifold control cable plug marked P18 to the 2-gang
manifold as shown.
2. Connect the 2-gang manifold control cable plug labeled P13 to the connector
labeled P13 on the rear of the power supply.