Section 6: Maintenance &Troubleshooting
Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
6-8
Gas Console
Code
Short Description
Long Description
20100
Plasma Adjust
Could not adjust Plasma Gas
20110
Shield Adjust
Could not adjust Shield Gas
20120
Preflow Adjust
Could not adjust Preflow Gas
20130
Postflow Adjust
Could not adjust Postflow Gas
20140
Marking Adjust
Could not adjust Marking Gas (Automatic Gas Console)
20160
N2 Mix Adjust
Could not adjust N2 Mix Gas
20170
O2 Mix Adjust
Could not adjust O2 Mix Gas
20200
O2 Low
O2 Input Pressure is low
20210
N2 Low
N2 Input Pressure is low
20220
Argon Low
Argon Input Pressure is low
20230
O2N2 Low
Air Input Pressure is low
20240
H17 Low
H17 Input Pressure is low
20250
O2 High
O2 Input Pressure is high
20260
N2 High
N2 Input Pressure is high
20270
Argon High
Argon Input Pressure is high
20280
O2N2 High
Air Input Pressure is high
20290
H17 High
H17 Input Pressure is high
20300
PS Quiet
Lost CAN communication with Power Supply
20310
PC Quiet
Lost CAN communication with Plasma Controller