TEST PROCEDURE FOR
NORMAL FIRING BOARD
OPERATION
1.
Disconnect main AC input power to
the IDEALARC DC-600.
2.
Locate the Firing Board on the left
side of Control Box facing the
machine.
3.
Perform a visual inspection of the
Firing Board to see if there are any
loose or faulty connections.
4.
Connect the correct main AC input
power to the machine.
5.
Set the ON/OFF PUSHBUTTON to
ON.
6.
Locate LEDs 7, 8, and 9 on the
Firing Board. See Figure F.7.
Each LED should be ON and be
equally bright. Use Table F.1 to
check the operation of each LED.
FIRING BOARD TEST
F-22
TROUBLESHOOTING & REPAIR
IDEALARC DC-600