FIRING BOARD TEST
IDEALARC DC-600
F-24
TROUBLESHOOTING & REPAIR
TABLE F.1 - LED 7, 8 and 9 Check List
IF
LED 7 is ON
THEN
AC power is being supplied to the Firing Board from
leads #203 and #204 connected to the phase angle
winding in the Main Transformer.
LED 7 is OFF or is
DIMMER than other LEDs
The proper AC voltage may not be reaching Firing
Board. Check for loose or faulty connections.
Perform Main Transformer Test.
LED 8 is ON
AC power is being supplied to the Firing Board from
leads #205 and #206 connected to the phase angle
winding in the Main Transformer.
LED 8 is OFF or is
DIMMER than other LEDs
The proper AC voltage may not be reaching Firing
Board. Check for loose or faulty connections.
Perform Main Transformer Test.
LED 9 is ON
AC power is being supplied to the Firing Board from
leads #207 and #208 connected to the phase angle
winding in the Main Transformer.
LED 9 is OFF or is
DIMMER than other LEDs
The proper AC voltage may not be reaching Firing
Board. Check for loose or faulty connections.
Perform Main Transformer Test.