INSTALLATION
A-2
Weight
522 lbs.
(237 kg.)
INPUT - THREE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
Standard Voltage
Duty Cycle
100%
60%
50%
Mode
Constant Current
Constant Voltage
Auxiliary Power
115 VAC, 8 Amps
Current
Range
90 to 850 Amps
70 to 850 Amps
Input Voltage /
Frequency
Fuse
(Super Lag)
or Breaker Size
Input Ampere
Rating on
Nameplate
2 (35mm
2
)
2 (35mm
2
)
6 (16mm
2
)
6 (16mm
2
)
6 (16mm
2
)
6 (16 mm
2
)
6 (16 mm
2
)
8 (10 mm
2
)
8 (10 mm
2
)
8 (10 mm
2
)
208/60
230/60
416/60
460/60
575/60
175
175
100
90
80
125
113
63
57
45
Type 75
o
C
Copper Wire in
Conduit AWG
(IEC) Sizes
Type 75
o
C
Copper Ground
Wire in Conduit
AWG (IEC) Sizes
Depth
39.0 in.
(988 mm.)
Width
22.25 in.
(567 mm.)
Height
30.75 in.
(781 mm.)
Maximum Open
Circuit Voltage
72 VDC
55 VDC
AMPS
600
680
750
Volts at Rated Amps
44
44
44
Input Current at Rated Output
208/230/416/460/575/3/60
125/113/63/57/45
TECHNICAL SPECIFICATIONS - IDEALARC DC-600
IDEALARC DC-600