IDEALARC DC-600
F-46
TROUBLESHOOTING & REPAIR
SCOPE SETTINGS
ABNORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
CONSTANT VOLTAGE INNERSHIELD
ONE OUTPUT SCR NOT FUNCTIONING
This is NOT the typical DC output voltage
waveform. One output SCR is not function-
ing. Note the “gap” in the waveform. One
SCR gate is disconnected to simulate an
open or non-functioning output SCR. Each
vertical division represents 20 volts and each
horizontal division represents 2 milliseconds
in time.
Note: Scope probes connected at machine
ouput terminals: (+) probe to positive termi-
nal, (-) probe to negative terminal.
Volts/Div . . . . . . . . . . . . . .20 V/Div.
Horizontal Sweep . . . . . . .2 ms/Div.
Coupling . . . . . . . . . . . . . . . . . . .DC
Trigger . . . . . . . . . . . . . . . . .Internal
0 volts
20 volts
2ms
CH 1