7
Wire Spool Loading
Wire spool type S300 and BS300 can be installed on the wire spool support without adapter. Wire spool type S200,
B300 or Readi-Reel
®
can be installed, but the applicable adapter must be purchased. The applicable adapter can be
purchased separately(see "Accessories" chapter).
Warning! Turn the input power OFF at the welding power source before installation or changing a wire
spool.
Wire Spool Type S300 or BS300 Loading
19
22
20
21
Turn the input power OFF.
Open the side panel.
Unscrew the Locking Nut [19] and remove it from the spindle [21].
Place the spool type S300 or BS300 [20] on the Spindle [21] making certain the Spindle Brake Pin [22] is put in
the hole in back side of spool type S300 or SB300.
Warning! Position the spool type S300 or SB300 so that it will rotate in a direction when feeding so as to be
de-reeled from bottom of the spool.
Re-install the locking nut [19]. Make sure that the locking nut is tightened.
Wire Spool Type S200 Loading
19
25
22
21
24
23
Turn the input power OFF.
Open the side panel.
Unscrew the Locking Nut [19] and remove it from the spindle [21].