background image

IS 607  ECN 4345 

Page 4 of 12 

 

 

 

INSTALLATION AND COMMISSIONING

 

 
 

This product is heavy; prior to installation a handling assessment should be made. 
 

This appliance must be earthed. An equipotential bonding terminal is provided to 
allow cross bonding with other equipment. 
 
Means of isolation with at least 3mm contact separation in all poles must be 

incorporated into the fixed wiring of this appliance. 
 
The fixed wiring insulation must be protected by insulated sleeving having a 
temperature rating of at least 60 Deg C. 
 
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary 
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57) 
 

 

Install this appliance beneath an extraction canopy. 

 

If using a stand fitted with castors, use caution at all times when manipulating or 
moving, and lock castors when appliance is in position. 
 
Install this appliance on a level surface ensuring all vents are unobstructed.  Any 
partitions, walls or furniture must be of non-combustible material (see Fig 1).  
Minimum distances A 100mm  B 1000mm. 
 

Electrical connection 

 
The electrical supply cable enters the unit through a cable gland in the rear panel. 
Connection of the electrical supply cable is to a terminal block behind the facia 
panel. The terminal block has a metal cover retained by two screws. 
 

 

 

 

Summary of Contents for Opus 800 OE8210

Page 1: ...tric Clam Griddle OE8210 OE8211 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number _______________...

Page 2: ...mation and Guarantee 11 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and not...

Page 3: ...e use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA OE8210 OE8211 Height mm 545 Width mm 800 400 Dept...

Page 4: ...ed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 Install this appliance beneath an extraction canopy If using a stand fitted with cas...

Page 5: ...IS 607 ECN 4345 Page 5 of 12 Fig 1...

Page 6: ...Clam plate Aluminium Fit the Teflon sheets to the clam plate before cooking Do not use the appliance without the Teflon sheets fitted Fig 2 A Amber neon clam head B Digital timer C Clam control knob D...

Page 7: ...to requirements at the time Shutting down Turn all the control knobs to the Off position and switch off at the isolating socket Be aware that the appliance will remain hot for some time CLEANING Your...

Page 8: ...ing clam neon and follow sequence as above Thermostat replacement On the griddle plate Remove the screws beneath the facia panel and remove the facia panel by rotating the bottom forward Remove the co...

Page 9: ...nd fit the replacement locating carefully reposition the cartridge beneath the griddle plate and tighten up the cartridge strap Fit stat bracket and facia by reversal of the above procedure On the cla...

Page 10: ...KN509 Control knob griddle LE38 Leg NE46 Green neon NE47 Amber neon SC01 Scraper TH110 Control thermostat TI40 Digital timer Part Number Description Used on OA8921 Floor stand OE8211 OA8956 Floor sta...

Page 11: ...ossible please tell us Brief details of the problem Product code All available on serial plate Type number Serial number Lincat reserve the right to carry out any work under warranty given reasonable...

Page 12: ...sed technician to carry out the warranty work Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Unless otherwise specified a maximum of 15 minutes...

Reviews: