background image

I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l  

Electric Griddle 

GP8600E 
GP8900E 
GP8120E 

 

Date Purchased 

Serial Number 

Dealer 

 

Service Provider 

 

229350-12 

 

For use in GB & IE 

I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l  

GPL8600E 
GPL8900E 
GPL8120E 

Summary of Contents for GP8600E

Page 1: ...e r a t i o n M a n u a l Electric Griddle GP8600E GP8900E GP8120E Date Purchased Serial Number Dealer Service Provider 229350 12 For use in GB IE I n s t a l l a t i o n a n d O p e r a t i o n M a n...

Page 2: ...1 0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NE...

Page 3: ...al Electrical Supply Requirements Electrical Connection Dimensions Installation 9 Installation Requirements Unpacking Location Clearances Assembly Electrical Connection Commissioning Operation 12 Oper...

Page 4: ...ION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS A...

Page 5: ...ddle 1200 mm wide Bench Model GP 1 8120E CB Electric Griddle 1200 mm wide with Cabinet Base GP 1 8120E LS Electric Griddle 1200 mm wide on Leg Stand GP 1 8120E RB Electric Griddle 1200 mm wide with Re...

Page 6: ...s per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g H05 RN F Type The branch supply line shall be individually overload protected to the correct current rating and the supply chord shall be protect...

Page 7: ...5 Dimensions GP L 8600E B GP L 8900E B GP L 8120E B Dimensions for Bench Models Rating Plate Location for this option R R...

Page 8: ...6 Dimensions GP L 8600E CB Dimensions for Cabinet Base Models Rating Plate Location for this option R GP L 8900E CB GP L 8120E CB R...

Page 9: ...7 Dimensions GP L 8600E LS GP L 8900E LS GP L 8120E LS Dimensions for Leg Stand Models Rating Plate Location for this option R R...

Page 10: ...8 Dimensions GP L 8900E RB GP L 8120E RB Dimensions for Refrigeration Base Models Rating Plate Location for this option R R...

Page 11: ...are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior stainless steel pa...

Page 12: ...ing the supply cable up through the grommet at the back of the appliance and through the compression type gland provided on the rear of the main electrical switchgear panel 5 Connect the mains supply...

Page 13: ...tor has been instructed in the areas of correct operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and as a record of Date of Purchase Date...

Page 14: ...supply the green neon will illuminate 2 Turn the thermostat control knob to the desired temperature When the amber neon goes out the desired temperature has been reached and the griddle is ready for u...

Page 15: ...down before cleaning NOTE DO NOT use abrasive detergents strong solvents or caustic detergents as they could corrode or damage the griddle In order to prevent the forming of rust on the griddle plate...

Page 16: ...e Steel Plate NOTE In order to prevent the forming of rust on the griddle plate ensure that all detergent and cleaning material has been entirely removed after each cleaning process The appliance shou...

Page 17: ...water a mild detergent solution and a soft scrubbing brush Note that the control knobs are a push fit onto the spindles and can be removed to allow cleaning of the front control panel b Baked on depo...

Page 18: ...on The Model Trade Name and the Serial Number of the Appliance both can be found on the Technical Data Plate located on the appliance Refer to the Dimensions section For the Refrigeration Cabinet Faul...

Page 19: ...EON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 7 11 22 32 12 3 P3 4 P4 CONTROL PANEL GRIDDLE PLATE 21 31 11 22 32 12 9 9 9 1 1 1 3 2 2 7 7 6 9 9 9 7 6 8 4 4 5 8 10 11 12 EARTH STU...

Page 20: ...EON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 7 11 22 32 12 3 P3 4 P4 CONTROL PANEL GRIDDLE PLATE 21 31 11 22 32 12 9 9 9 1 1 1 3 2 2 7 7 6 9 9 9 7 6 8 8 4 4 5 10 10 11 12 EARTH...

Page 21: ...DLE PLATE 21 31 11 22 32 12 15 16 15 16 REAR SUPPLY ENTRY THERMOSTAT 229146 SWITCH 229145 2 1 P2 P1 NEON AMBER 227963 NEON GREEN 227962 OVERTEMP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4 21 31 11...

Page 22: ...EON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4 21 31 11 22 32 12 THERMOSTAT 229146 SWITCH 229145 2 1 P2 P1 NEON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31...

Page 23: ...Models only 228801 Refrigeration Base 900 mm Plinth Kit RB Models only 228805 Refrigeration Base 1200 mm Plinth Kit RB Models only 227850 Leg 150 mm Adjustable Flush Stud CB and RB Models 227851 Leg 1...

Page 24: ......

Reviews: