CLEANING

 

 

 
Do not use a water jet or steam cleaner, and do not immerse this appliance. 

 

Clean all panels with warm water and mild detergent, do not use abrasive    

materials.  Dry with a soft cloth. 

 

Slide out and empty the drip tray regularly, and wipe the dispensing nozzle daily to   
remove limescale deposits. 

 
 

De-scaling 

 

The boiler should be de-scaled regularly to maintain efficient operation and water 
quality.  The frequency depends on the hardness of the water and timely 
replacement of the filter. 

 

 

The de-scaling procedure must be performed by trained personnel as it 
requires the removal of panels from the boiler giving access to live electrical 
components. 

 

 

 
De-scaling the boiler at the end of the working day gives the de-scaling agent 
several hours to work.  Lincat recommend our own de-scaling agent MS19, 
available from our Spares department. 

 
 

Wear protective clothing. 

 
 

Isolate the boiler from the electrical supply. 

 
 

Turn off the power and allow the water to cool to 60 Deg C. 

 
 

Using a 3mm allen key, remove the screw in the top of the boiler. 

 
 

Remove the insulation from the top of the tank.  Unscrew and remove the tank lid. 

 

Add the de-scaling agent slowly to avoid eruption of the water, following the 
manufacturers instructions. 

 

Replace tank lid and outer lid and attach an „Out of Use‟ notice to prevent use 
during de-scaling. 

 

Turn on the electricity and run the boiler normally for 30 minutes.  Isolate the boiler 
and allow the water to cool. 
 
Remove both outer and tank lids again.  Inspect the tank and level sensor housings 
for scale deposits.  If necessary, repeat the de-scaling process. 
 
Drain and flush de-scaling agent as follows: 
 

Summary of Contents for EB3F/PB

Page 1: ... Button Water Boilers EB3F PB and EB3F PBM Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Page 2: ...rmation and Guarantee 11 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your Lincat...

Page 3: ... all times Strip plastic coating and clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model Height mm Width mm Depth mm Weight kg EB3F PB 655 290 465 13 0 CHECK LIST OF ENCLOSURES Warranty card Instructions manual Drip tray and insert Inlet hose with BSP connection FilterF...

Page 4: ...mounting kits see Accessories Power Ratings Model kW Ambient temperature Deg C Water inlet pressure bar Water inlet pressure kPa EB3F PB 3 0 5 to 30 1 to 8 100 to 800 The EB3F PB is supplied with a 13 amp plug Water supply and waste connection Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the supply via an accessible isolat...

Page 5: ...IS425 ECN 3607 Page 5 of 13 OPERATING INSTRUCTIONS Fig 1 ...

Page 6: ...e Water is drawn off through the dispenser G Adjustment Water temperature screen backlight and contrast Consult Fig 1 Turn power off and on again The FilterFlow screen B is displayed on the control panel A Press and hold the power button D until the software version is displayed Press the function button Fn C and the temperature will be displayed Press the power button to cycle through the values ...

Page 7: ...After a few seconds the programming mode is entered Push the Fn button until the Use dispense screen is visible Pressing set turns off the timed dispense and the unit changes to Push and hold for dispensing Press next Press set to select 1 2 or 3 measured dispenses Press next Press yes to select to set the dispense volumes Or next to exit Select the size to set Press OK Press and hold the Hot wate...

Page 8: ...e used without a filter but scale will quickly build up and water taste may be affected Fig 2 To replace the filter Remove the drip tray from the appliance Pull the bottom of the lower panel Fig 1 F outwards and release the two spring pins Slide the panel downwards to remove Twist the base of the filter 90 degrees to the left and lower the cartridge out of the appliance It will contain a small amo...

Page 9: ...working day gives the de scaling agent several hours to work Lincat recommend our own de scaling agent MS19 available from our Spares department Wear protective clothing Isolate the boiler from the electrical supply Turn off the power and allow the water to cool to 60 Deg C Using a 3mm allen key remove the screw in the top of the boiler Remove the insulation from the top of the tank Unscrew and re...

Page 10: ... on these appliances should be carried out by one of our recommended service engineers The control panel displays information that can help with fault diagnosis Before calling for service draw off a litre of water clear the fault code by pressing the Fn button and turn the boiler off and on again at the supply If the fault persists call service for advice Message displayed Possible causes Correcti...

Page 11: ...zle DV02 Service valve EBM05 Outer lid EL235 Element FC02 Filter cartridge FH02 Filter head GA48 Lid gasket LE47 Level sensor insulator LE48 Upper level sensor LE49 Lower level sensor PI12 Inlet hose PL202 Mains cable PR77 Circuit board SO24 Solenoid valve SV03 Dispenser solenoid valve SW86 Dispenser switch TH87 95o cutout thermostat TH88 120o cutout thermostat TH98 Thermistor SPARE PARTS LIST FIL...

Page 12: ...an routine cleaning should be carried out by one of our authorised service agents We cannot accept responsibility for work carried out by other persons To ensure your service enquiry is handled as efficiently as possible please tell us Brief details of the problem Product code All available on serial plate Type number Serial number Lincat reserve the right to carry out any work under warranty give...

Page 13: ...ufacturer disclaims any liability for incidental or consequential damages Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Unless otherwise specified a maximum of 15 minutes of administrative time not spent directly carry...

Reviews: