If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed.
The serial plate is located on the side of the appliance Fig 1 (H).
Instructions for wall mounting are supplied with the wall mounting kits (see
Accessories).
Power Ratings
Model
kW
Ambient
temperature Deg C
Water inlet pressure
(bar)
Water inlet
pressure (kPa)
EB3F/PB
3.0
5 to 30
1 to 8
100 to 800
The EB3F/PB is supplied with a 13 amp plug.
Water supply and waste connection
Connect the supplied white water inlet hose to the inlet connection point on the
base of the boiler and the other end to the supply via an accessible isolating tap
with a ¾” BSP thread.
If required, the drip tray can be connected to a waste water outlet using a ½”
bulkhead connector (not supplied). Knock out the blank in the tray base. If cables
are required to exit at either side of the boiler the thinner section between the
moulded base sides may be cut away with a hacksaw.